DSR-80/80P (Skip this step in the DSR-60/60P.)
9. Playback the alignment tape XH5-1A2/XH5-1AP2. Select �15O� in the parentheses ( ) in the top right with the [*] key and select DELAY with the [*] key at the same time. Perform adjustment until the data becomes nearly the minimum value (000X) using the [(], [)] keys.
10. Playback the alignment tape XH4-1A/XH4-1AP. Select �10E� in the parentheses ( ) in the top right with the [*] key and select PHASE with the [*] key at the same time. Perform adjustment until the data becomes nearly the minimum value (000X) using the [(], [)] keys.
11. Playback the alignment tape XH4-1A/XH4-1AP. Select �10E� in the parentheses ( ) in the top right with the [*] key and select COS with the [*] key at the same time. Perform adjustment until the data becomes nearly the minimum value (000X) using the [(], [)] keys.
12. Playback the alignment tape XH4-1A/XH4-1AP. Select �10E� in the parentheses ( ) in the top right with the [*] key and select AGC with the [*] key at the same time. Perform adjustment until the data becomes nearly the minimum value (000X) using the [(], [)] keys.
4-36
DSR-80/80P/60/60P
|
|
 |
> |
|