No hay comentarios de productos.
PANEL MECHANISM DESCRIPTION
A. Panel Opening
1. When Open button(switch) is pressed, the motor (305) rotates. 2. The rotation of the motor is transmitted forward through the rack gear (316) via the gears (320-322) 3. When the rack gear (316) moves, the panel (PA1) goes down.
2
DPX-5010
B. Closing Behavior
1. The motor rotates in reverse direction. 2. The arm assembly (304) goes up. When the lever (A) goes into the lock position of the rail (312), the arm assembly (304) stops going up.
4 304
3 3 305 304 308 309 2 312
1
302
316
320 321
3. When the arm assembly (304) stops, by the rotation of the planetary gear (303), the motor rotation pushes the rack gear (316) backward via the gears (320-322). 4. By the close position information of the LPS (342), the motor (305) stops after 200mS.
4. (1) The upper side of the panel pushed on the arm assembly (304) by the pin (�2) and the groove of the rail (�3). (2) The lock on the lever (A) is let go and the arm assembly (304) goes down. (3) When this happens, the planetary gear (303) rotates. 5. When the arm assembly goes down to the open position, the switch (341) is turned on. When the switch (341) is turned on, the motor stops after 950ms.
312 3 308 303 320
305 304 308 309
303 304 320 1 2 3 4 2 A 304 302 316 321
C. Angle Behavior
1. By the position information of the LPS (342), the panel angle is controlled.
341
304