No hay comentarios de productos.
DNV 3360 - DNI 3360 DNHI 3460 - DNHV 3460
PRODUCT DESCRIPTION SHEET
CONTROL PANEL
1
A. Light switch. B. Speed selector. C. Intensive extraction (only for models DNHI 3460 and DNHV 3460).
4 2 3
1. Control panel 2. Grease filter (inside the extractor grille) 3. Lighting unit 4. Pull-out steam deflector
0123
C
0I
A
B
large amount of steam and fumes medium amount of steam and fumes small amount of steam and fumes
RENEWING BULBS
1. Unplug the appliance or switch off the mains power supply. 2. Pull out the steam drawer. 3. Open the rear extractor grille. 4. Remove the burnt-out bulb and insert a new one. Use only 40W max (E14) bulbs. 5. Remount the extractor grille.
25 24
CLOSED
CLOSED
OPEN
OPEN
REMOVING AND RENEWING OR CLEANING THE GREASE FILTER:
1. Unplug the appliance or switch off the mains power supply. 2. Pull out the steam drawer. 3. Remove the extractor grille. 4. Release the grease filter. 5. Remove the dirty grease filter. 6. After renewing or cleaning the grease filter (depending on model) repeat the above steps in reverse to reassemble, making sure the entire extraction surface is covered.
24
24
MOUNTING OR RENEWING THE CARBON FILTER:
a
1. Unplug the appliance or switch off the mains power supply. 2. Pull out the steam drawer. 3. Remove the extractor grille. 4. If a carbon filter is already mounted and needs renewing, press the release buttons (b) and pull the filter out downwards. 5. If the filters are not mounted. a. fit the carbon filter into the upper clips. b. fasten using the lower clips. 6. Remount the extractor grille.
b
E P I GR
D
5019 100 75016
GB
F
NL
|