In this unit, about 10 seconds after power is supplied (8.4V) to the battery terminal using the service power code (J-6082-223-A), the power is shut off so that the unit cannot operate. These following two methods are available to prevent this. Take note of which to use during repairs. Method 1. Use the DC IN terminal. (Use the AC power adaptor.) Method 2. Connect the adjustment remote commander RM-95 (J-6082-053-B) to the LANC jack, and set the HOLD switch to the �ADJ� side.
2.
1 2 3 4 5 6 7 8 9
TO TAKE OUT A CASSETTE WHEN NOT EJECT (FORCE EJECT)
Refer to 2-2. to remove the front panel section. Refer to 2-3. to remove the cabinet (upper) section. Refer to 2-3. to remove the cabinet (R) section. Refer to 2-4. to remove the lens section. Refer to 2-5. to remove the EVF section. Refer to 2-6. to remove the battery panel section. Refer to 2-8. and 2-9. to remove the cabinet (L) section. (Include the CS frame assembly and control switch block (SS-1380).) Disconnect CN4401 (2P) of VC-276 board. Add +5V from the DC POWER SUPPLY and unload with a pressing the cassette compertment.
0 Pull the timing belt in the direction of arrow A with a pincette while pressing the cassette compartment (take care not to damage) to adjust the bending of a tape.
Pincette
A
Timing belt
Press the cassette compartment not to rise the cassette compartment
qa Let your hold the cassette compartment and rise the cassette compartment to take out a cassette.
Timing belt
DC power supply (+5V) Adjust the bending of a tape Loading motor Disconnect CN4401 of VC-276 board