1-1-2. Preparations Note 1: For details of how remove the cabinet and boards, refer to �2. DISASSEMBLY�. 1) Connect the equipment for adjustments according to Fig. 5-1-3. 2) Connect the adjustment remote commander to the CN805 on the VA-103 board via CPC-5 (J-6082-351-A).
Pattern box
L
Front side of the lens
L = About 40 cm
Fig. 5-1-2
Audio (L) Audio (R)
Color monitor Video CPC-5jig (J-6082-351-A) Remote terminal
Vectorscope 75 � terminated
Camera head
Adjustment remote comander (RM-95) (J-6082-053-B)
CN805 CN301 Regulated power supply (8.4 V ± 0.1 Vdc) VA-103 board CN803 CN802 CS-53 board Video/Audio output terminal
CN801
CN303
CN601
Note 2: In changing data, wait for more than 5 seconds after the set was turned on, then change the data.