29.Remove wiring connectors of the compressor cord by using longnose pliers.(3 parts) Then turn the band to the direction, as shown in below figure. CAUTION: RETURN THE BAND TO THE ORIGINAL DIRECTION WHEN RE-ASSEMBLYING.
CAUTION: DISCHARGE THE FAN MOTOR CAPACITOR AND RUNNING CAPACITOR BEFORE TOUCHING THESE CAPACITORS OR OTHER COMPONENTS OR WIRING. 30.Unscrew 2 screws holding the control box. Remove the control box from the unit.
33.Move the band to the direction shown in below figure (approx.11/ 16"). Then removed the drain hose B.
34.Unscrew the screw holding the lead wire. 31.Unscrew 6 screws holding the casing cover. Remove the casing cover from the unit.
35.Turn the band, as shown in below figure. CAUTION: RETURN THE BAND TO THE ORIGINAL DIRECTION WHEN RE-ASSEBLYING. 32.Unscrew 4 screws holding the orifice. Remove the orifice from the unit. Move the band to the direction of the arrow(approx.11/16"), and removed the drain hose A.