an upper limit of 31°C and a lower limit of 16°C.)
1. While operation is stopped, press the TEMP UP and TEMP DOWN buttons simultaneously.
2. To set an upper limit Press the OPERATION button until HEAT is displayed. / / Press the TEMP UP or TEMP DOWN button to set the temperature. / / Press the SET button to complete the upper limit setting. / Example: / If the heating display is set to 28°C, setting the temperature to higher than 28°C will not be possible. / * Upper and lower limits cannot be set at the same time. 3. To set a lower limit Press the OPERATION button until COOL is displayed. / / Press the TEMP UP or TEMP DOWN button to set the temperature. / / Press the SET button to complete the lower limit setting. / Example: / If the cooling display is set to 22°C, setting the temperature to lower than 22°C will not be possible. / * Press the CANCEL button to cancel the setting. 23.2. Switching to the remote control thermistor - The temperature detection thermistor used for detecting the indoor temperature can be switched between the thermistor at the indoor