|
Usuarios conectados
Actualmente hay 5984 visitantes online.
|
Productos
|
Información
|
Destacado
|
|
|
|
|
No hay comentarios de productos.
11 Schematic Diagrams
11-1 Cautions
1. The areas marked with a ! , or on the schematic diagram designate components which have special characteristics important for safety. Replace these parts only with parts identical to those in the original circuit and those specified in the parts list. Before replacing any of these components, carefully read the �Product Safety Notice.� 2. Areas marked with a on the schematic diagram designate controls which have been sealed for safety during manufacturing. If these controls need adjustment, they must be replaced with new controls and then sealed after their adjustment. 3. When taking measurements, pay special attention to the following: 1) Do not use your instrument between primary ground (symbol 2) Do not use your instrument between secondary ground (symbol ) and secondary circuit. ) and primary circuit.
11-2 Notes
1. Resistance is shown in OHM. K = 1,000, M = 1,000,000 and the rated power of resistors not noted in the schematic diagram is 1/4W. 2. Capacitance is shown in µF. Capacitances not otherwise noted are shown in pF (1µF = 1,000,000 pF). Rated voltage of condensers not otherwise noted in the schematic diagram is 50 V.
11-3 Abbreviations and Symbols
MO FU CM MP P R-Metal Oxide Fusible R-Cement C-Metalized Polyester C-Polyester Hot Ground Electrostatically Sensitive Device (ESD) ! WW C MPP T R-Wire Wound R-Composition Metal Polypropylene C-Tantalum Can emit X-radiation Cold Ground Provides special safety considerations
1. The secondary voltage is read with an SSVM from the indicated point to a cold ground ( ). The primary voltage is read with an SSVM from the indicated point to a hot ground ( ). 2. This schematic diagram is subject to change without notice.
CKB5237L/7227L
11-1
|
|
|
> |
|