|
Usuarios conectados
Actualmente hay 5734 visitantes online.
|
Productos
|
Información
|
Destacado
|
|
|
|
|
No hay comentarios de productos.
CDX-M8086ZT ,M8086ZT-91,M8186ZT ,M8186ZT-91
1 Tracking Error Offset Adjustment 1
�Purpose : To adjust the offset of the tracking servo to zero. �Symptoms of Mal-adjustment : Track search NG, carriage runaway, poor playability.
2 Grating Check / Adjustment 1
�Purpose : To check that the PU grating is correctly aligned after the PU unit has been replaced. �Symptoms of Mal-adjustment : Unable to play disc, track skip during search, search NG. �Measuring Equipment / Jig �Measuring Point �Test Disc , Mode �Adjustment Point �Oscilloscope, Two L.P.F., Clock Driver �E, F �ABEX TCD-784 (or SONY TYPE 4), TEST MODE �Grating hole
�Measuring Equipment / Jig �Measuring Point �Test Disc , Mode �Adjustment Point
�DC V Meter �TEY �No disc, TEST MODE �VR1001(TE OFFSET VR)
MAIN UNIT
REFO
MAIN UNIT
L.P.F.
F REFO E
100kW 390pF
X Oscilloscope
Y
TEY
L.P.F. 100kW 390pF
TEY
REFO
DC V Meter
Adjustment Procedure 1.Switch the regulator on. 2.Using VR1001(TE OFFSET) adjust DC voltage of TEY from REFO to 0±25mV.
Adjustment Procedure 1.Load disc and switch regulator on. 2.Position the PU unit in the center of the disc using the TRK UP and TRK DOWN keys. 3.Press key RPT to close focus and press once more to close spindle. 4.Input the L.P.F. output of E to the X axis, and L.P.F. output of F to the Y axis of an oscilloscope by the AC mode, observe lissajous, and check that the grating is within ±45°. (See Waveform 1�3). 5.If the grating is over 45°, make a fine adjustment by slowly turning the screw driver, so that the lissajous is in line. If, however during the adjustment the screw driver should be turned too much and the lessajous should become out of line, proceed to the next grating adjustment 2.
36
|
|
|
> |
|