� Mode for checking the load on the Jog dial
A
In this mode, the load (light/heavy) on the Jog dial while it is rotated is subjectively measured.
JOG Check Mode : ON
CALL POWER SW
+
FWD+ REV
B
POWER ON
FL display
Rotation speed
Time (msec)
Measuring method
C
In this state, if you rotate the Jog dial rapidly either clockwise or counterclockwise, figures are displayed. For example, if "16.14 0135" is displayed, it means as follows: 16.14: Highest speed (given that the normal [1x] speed is when it takes 1.8 sec for the Jog dial to rotate one full turn.) 0135: Time (msec) required for the Jog dial to decrease its speed from 3x speed to 1.5x speed As to the time required for the Jog dial to decrease its speed, if the measurement is performed for several times repeatedly, from the second measurement and afterward, the average of the current required time and the previous required time is displayed. Thus, after several measurements, the result becomes closer to the mean. Notes � Perform the measurement of load on the Jog dial more than three times. � The measurement result is displayed only when the Jog dial is rotated 7 times normal speed "07.00" or more.
D
Management value
Jog management value: 150 ± 25 (msec)
Load adjustment method
Remove the screw fixing the adjust plate, then screw it into the hole corresponding to the value (-1, -2, -3, +1, or +2) for a load to be added: -1, -2, -3 : To decrease the load +1, +2 : To increase the load