ELZD5560 IN Quantity: 1
$4.99
» View Details
29PT6807/69 Quantity: 1
$4.99
» View Details
VSX-AX4AVI-G/SAXJ Quantity: 1
$4.99
» View Details
DEH-P6400R Quantity: 1
$4.99
» View Details
ET22PKXBN00 Quantity: 1
$4.99
» View Details
TX-24WG10X Quantity: 1
$4.99
» View Details
HDL 10 W Quantity: 1
$4.99
» View Details
PD-42WV74S Quantity: 1
$4.99
» View Details
ARL 655/H Quantity: 1
$4.99
» View Details
SAVANNAH CR127 Quantity: 1
$4.99
» View Details
TE1029V Quantity: 1
$4.99
» View Details
14N21IS Quantity: 1
$4.99
» View Details
ET14AK2LWR0 Quantity: 1
$4.99
» View Details
AYXP12DRNC Quantity: 1
$4.99
» View Details
AS64025 Quantity: 1
$4.99
» View Details
CA55AP Quantity: 1
$4.99
» View Details
VSX-D714-S/SFXJI Quantity: 1
$4.99
» View Details
SF387PEYN0 Quantity: 1
$4.99
» View Details
AG-DVC180AMC Quantity: 1
$4.99
» View Details
KD-S7350 Quantity: 1
$4.99
» View Details
I638 Quantity: 1
$4.99
» View Details
GD5SHAXKQ02 Quantity: 1
$4.99
» View Details
AWE/D 1009 EX Quantity: 1
$4.99
» View Details
KSSS36MHX00 Quantity: 1
$4.99
» View Details
AKP 353 WH Quantity: 1
$4.99
» View Details
ARC7559AQUA Quantity: 1
$4.99
» View Details
DV-525/RD/RB Quantity: 1
$4.99
» View Details
955/515 Quantity: 1
$4.99
» View Details
VZ9456E1 Quantity: 1
$4.99
» View Details
SJP83800 Quantity: 1
$4.99
» View Details
GZ-MG27EX Quantity: 1
$4.99
» View Details
1587AVS Quantity: 1
$4.99
» View Details
JS48FSDBDA Quantity: 1
$4.99
» View Details
RC26SN Quantity: 1
$4.99
» View Details
GRDVL220UB Quantity: 1
$4.99
» View Details
ET20HDXBN00 Quantity: 1
$4.99
» View Details
SU-A80 Quantity: 1
$4.99
» View Details
AWE 2517 Quantity: 1
$4.99
» View Details
Subtotal: $189.62
 
English Polski Spanish 
Buscar un manual
 

(p.Ej. AA-V20EG JVC, ZX-7 Sony)
PayPal 1000+ rating Secure, Encrypted Checkout.
 
Usuarios conectados
Actualmente hay 5845 visitantes online.
Productos
Información
Destacado
Inicio >> SHARP >> AH-X095E Manual de Servicio
 
 38 artículo(s) en Su carrito 

SHARP AH-X095E
Manual de Servicio


¡Twitee acerca de este producto y obtenga $1.00 de crédito en la tienda para uso!
  • Contiene diagramas del circuito
  • Descargable
  • Formato PDF
  • Manual completo
  • Idiomas: English
Precio: $4.99

Descripción del SHARP AH-X095E Manual de Servicio

Manual de servicio completo en formato digital (archivo PDF). Los manuales de servicio por lo general contienen diagramas de circuitos, tarjetas de circuitos impresos, consejos para reparación, diagramas de cableado, diagramas de bloque y lista de refacciones. El Manual de Servicio (a veces llamado Manual de Reparación) es usado principalmente por los técnicos.

Si tan solo quiere saber cómo utilizar su televisión, reproductor de vídeo, reproductor de mp3, etc. Quizá lo que necesita es el Manual del Propietario. Después de colocar la orden le enviaremos las instrucciones de descarga a su dirección de e-mail.

The manual is available in languages: English

Not yet ready
You must purchase it first

Opiniones de los clientes
No hay comentarios de productos.

TEXT_PDF_SNIPPET
AH-X075E/X095E AU-X075E/X095E AY-X075E/X095E AE-X075E/X095E

2-3 Overcurrent protection (1) Compressor lock detection If the set value (3.0 A) of AC current is exceeded at 19 to 23 Hz when operation begins, operation is stopped. In this case, the compressor outdoor fan does not stop, and 170 seconds after operation is stopped, another try will be made. Three retries are allowed. On the fourth retry, a complete stop request signal is sent to the indoor unit, and the outdoor unit will remain stopped until reset is performed. At this time, the 3-minute delay for control of the outdoor unit will not function; therefore, do not cancel by removing the plug and cutting the power. (2) DC overcurrent detection, AC overcurrent detection To protect against overcurrent due to sudden changes in load, the compressor is stopped if the set value 30 A DC is exceeded in the DC section, or the set value 8.5 A AC is exceeded in the AC section. In this case, the outdoor fan does not stop, and 170 seconds after operation is stopped, another try will be made. Three retries are allowed. On the fourth retry, a complete stop request signal is sent to the indoor unit, and the outdoor unit will remain stopped until reset is performed. At this time, the 3-minute delay for control of the outdoor unit will not function; therefore, do not cancel by removing the plug and cutting the power. 2-4 Compressor protector control If the temperature of the compressor chamber exceeds 114°C, the compressor is stopped. In this case, the outdoor fan does not stop, and when the compressor chamber temperature decreases to 100°C three minutes after operation is stopped, another try will be made. Three retries are allowed. On the fourth retry, a complete stop request signal is sent to the indoor unit, and the outdoor unit will remain stopped until reset is performed. At this time, the 3-minute delay for control of the outdoor unit will not function; therefore, do not cancel by removing the plug and cutting the power. 2-5 Power transistor module protector If the temperature of the chips in the power transistor module exceeds 105 °C, the compressor is stopped. In this case, the outdoor fan does not stop, and when the temperature of the chips in the power transistor module decreases to 105 °C 170 seconds seconds after operation is stopped, another try will be made. Three retries are allowed. On the fourth retry, a complete stop request signal is sent to the indoor unit, and the outdoor unit will remain stopped until reset is performed. At this time, the 3-minute delay for control of the outdoor unit will not function; therefore, do not cancel by removing the plug and cutting the power. 2-6 Power factor module If a voltage error (over 400 V), current error (over 17 A), or temperature error (over 90°C) is detected in the power factor module, 170 seconds the compressor is stopped. In this case, the outdoor fan does not stop, and 170 seconds after operation is stopped, another try will be made. Three retries are allowed. On the fourth retry, a complete stop request signal is sent to the indoor unit, and the outdoor unit will remain stopped until reset is performed. At this time, the 3minute delay for control of the outdoor unit will not function; therefore, do not cancel by removing the plug and cutting the power. 2-7 Serial signals (1) Serial signals consist of all 96-bit signals. (2) If the outdoor unit does not receive a serial signal, it will stop approximately 30 seconds later. Note that this is true only of normal operation; in test mode, it does not stop and operation takes place based on the test mode commands. 2-8 Four-way rotary valve The four-way rotary valve will not switch when there is a large difference in refrigerant pressure. To make the four-way rotary valve switch normally, switching is delayed by approximately 3 minutes and the refrigerant pressure difference is decreased first. Also, the temperature of the indoor heat exchanger at the time of compressor activation and the temperature 150 minutes after activation are compared, and it is determined whether or not they are suitable for the operating mode at that time. If they are not suitable, a four-way rotary valve error results and the compressor is stopped.

27

Quizás también quiera comprar

$4.99

AH-X095E SHARP
Manual de Usuario

Manual del propietario completo en formato digital. El manual estará disponible para descarga como …
>
Parse Time: 0.458 - Number of Queries: 239 - Query Time: 0.083