DVT-14H1P Quantity: 1
$4.99
» View Details
CDI360/00C Quantity: 1
$4.99
» View Details
107E66/27B Quantity: 1
$4.99
» View Details
4KFPM770NK0 Quantity: 1
$4.99
» View Details
RS25AGXNQ00 Quantity: 1
$4.99
» View Details
4KSRS25QAA01 Quantity: 1
$4.99
» View Details
XL-Z674BK Quantity: 1
$4.99
» View Details
KSRG22FKBT05 Quantity: 1
$4.99
» View Details
TGP310LW4 Quantity: 1
$4.99
» View Details
RC8400XVW1 Quantity: 1
$4.99
» View Details
ET14JMXMWR6 Quantity: 1
$4.99
» View Details
RT14BKXGW00 Quantity: 1
$4.99
» View Details
SRF59 Quantity: 1
$4.99
» View Details
SLX4 Quantity: 1
$4.99
» View Details
SD-4000 Quantity: 1
$4.99
» View Details
RS252R6 Quantity: 1
$4.99
» View Details
KGCS105GAL2 Quantity: 1
$4.99
» View Details
NWE95 Quantity: 1
$4.99
» View Details
HMDA440 Quantity: 1
$4.99
» View Details
KESC300BAL8 Quantity: 1
$4.99
» View Details
CCD-TRV30PK Quantity: 1
$4.99
» View Details
2131 Quantity: 1
$4.99
» View Details
Subtotal: $109.78
 
English Polski Spanish 
Buscar un manual
 

(p.Ej. AA-V20EG JVC, ZX-7 Sony)
PayPal 1000+ rating Secure, Encrypted Checkout.
 
Usuarios conectados
Actualmente hay 5184 visitantes online.
Productos
Información
Destacado
Inicio >> TEKTRONIX >> 7D15 Manual de Servicio
 
 22 artículo(s) en Su carrito 

TEKTRONIX 7D15
Manual de Servicio


¡Twitee acerca de este producto y obtenga $1.00 de crédito en la tienda para uso!
  • Contiene diagramas del circuito
  • Descargable
  • Formato PDF
  • Manual completo
  • Idiomas: English
Precio: $4.99

Descripción del TEKTRONIX 7D15 Manual de Servicio

Manual de servicio completo en formato digital (archivo PDF). Los manuales de servicio por lo general contienen diagramas de circuitos, tarjetas de circuitos impresos, consejos para reparación, diagramas de cableado, diagramas de bloque y lista de refacciones. El Manual de Servicio (a veces llamado Manual de Reparación) es usado principalmente por los técnicos.

Si tan solo quiere saber cómo utilizar su televisión, reproductor de vídeo, reproductor de mp3, etc. Quizá lo que necesita es el Manual del Propietario. Después de colocar la orden le enviaremos las instrucciones de descarga a su dirección de e-mail.

The manual is available in languages: English

Not yet ready
You must purchase it first

Opiniones de los clientes
No hay comentarios de productos.

TEXT_PDF_SNIPPET
Operating Instructions-7D15 MODES OF OPERATION Manual Stop Watch This mode uses the GATE ON OFF switches to manually turn the counter main gate on and off . The counting rate is determined by the CLOCK switches . Times of up to 10 5 s can be measured in this mode . Event Counter In the EVENTS mode, the 7D15 counters accept information from the B Input connector. The B TRIGGER 1 controls select the counter triggering point. From to . 108 events can be counted in this mode Frequency Measurements The 7D15 can measure frequencies directly from do to 225 MHz when used in the FREQ mode . To obtain greater resolution of low-frequency measurements, measure the period of the waveform and calculate frequency (Frequency = 1/Period). Frequency Ratio Measurements The ratio of one signal to another can be compared with a range of up to 104 :1 and, depending on the range, a resolution of up to 10-7 . In the Frequency Ratio mode, the "standard" or reference signal is usually connected to the EXT CLOCK IN and the signal to be compared is connected to the B Input connector.
-PERIOD-~ PERIOD PERIOD AVERAGED (X10) B. PERIOD AVERAGED

Time Interval Measurements (TIM) Two basic modes of time interval measurements can be selected, TIM WIDTH, and TIM A-B . The TIM WIDTH mode measures the time between two points on a waveform . These points are selected by the A TRIGGER controls such that the counter main gate turns on at the point on the waveform selected by the A SLOPE and LEVEL controls and turns off at the same level but on the other slope. See Fig. 2-7c. the TIM WIDTH mode, The TIM A-B mode, like measures the time between two points on a waveform . These two points are controlled individually, such that the A TRIGGER controls select the point on the waveform that turns the main gate on, and the B TRIGGER controls select the point on the waveform that turns the main gate off. See Fig. 2-7d .

Period Measurements and Period Averaging The 7D15 measures periods from 10 ns to 10 5 s . Up to 1000 periods can be averaged to obtain a resolution of up to 10 ps . The period mode measures the time between two points on a waveform . These two points are selected by the A TRIGGER controls such that the counter main gate turns on and off at the point selected by the level and slope controls, see Fig. 2-7a . The period averaging mode holds the

A.

I

C. +SLOPE HYSTERESIS WINDOW -SLOPE

TIM WIDTH A

A INPUT D. TIME INTERVAL B INPUT TIM A-rB

r

TIME INTERVAL

1432-13

Fig. 2-6 . Measurement intervals .

2-7

Quizás también quiera comprar

$4.99

7D15 TEKTRONIX
Manual de Usuario

Manual del propietario completo en formato digital. El manual estará disponible para descarga como …
>
Parse Time: 0.208 - Number of Queries: 177 - Query Time: 0.053