32PD5000/42PD5000 (PW1)
6. Adjustment
� How to get to Adjustment mode Using the front control buttons with the set turned off (standby) can activate it. Press the SUB-POWER( ) button, INPUT SELECT( more than 5 seconds. The set turns on in adjustment mode with OSD. � Changing data and Selecting Adjustment code When the set is in adjustment mode, the cursor , , , and OK buttons of the remote control or front panel may be used as the adjustment keys. , buttons are used for selecting adjustment code. , buttons are used for changing data values. OK button is used for confirming the data. After finishing the necessary adjustment press MENU button. Adjustment mode is released and the set returns to normal condition. � Memory Initialize operation NOTE: The execution of this function returns the adjustment codes to the preset values, therefore, adjustment data will be lost. Procedure (1) Enter Adjustment Mode. (2) Select MEMORY INIT adjustment code (No.704) and change the data value from 0 to 1. (3) Activate MEMORY INIT by pressing OK button for more than 3 seconds. (4) Select No.374 and change data value from 1 to 0. (5) Check that the receiving channel goes to AV1. Unit is set to preset values. ) button and button at the same time, and hold for
15
|