Adjustment Preparations Adjustment Procedures (1) Turn on the set and perform (1) Turn Vs ADJ to adjust Vs voltage pre-heat run more than 1 to be within ±0.1V of the value min with burn-in screen. specified in the label on the panel.
Remarks Permissive level of voltage in sufficient time of heat-run performed is: Vs: within±0.45V Va: within±0.55V
(2) Receive full back pattern signal (or Video silence signal; it will be automatically turned off after a few seconds by power save function.)
(2) Turn Va ADJ to adjust Va voltage to be within ±0.2V of the value specified in the label on the panel.
(3) Connect voltmeter leads (3) Reconfirm that Vs voltage remains to Vs (or Va) and GND within ±0.1V of the specified value. test points of the power unit. Readjust if it� s outside of the margin. Label example <LOT>N6 Vs= 185.0V Va=65.0V Label position (Reference) Upper right If it� s hard to read the voltage value because of the wiring, highlight it in advance to be visible.