G2, Cut Off and Gain Adjustments (alternative method). In the event off a Colorimeter not being available, please follow the following procedures to obtain correct G2 and Grey scale settings. 1. Tune the set to the output of a RF signal generator (cross hatch pattern). 2. In the user menu, set the picture levels to the FACTORY settings. 3. In the user menu, set the tint control to its central position. 4. Enter the service mode. 5. Set the ABL levels in the NVM by adjusting positions 60, 61, 62, 63, 64 and 65 on page 00 to read 80. Store each location by pressing the stand-by button on the remote control. 6. Adjust the G2 and grey scale as below. When adjusting the grey scale the following boxes will appear on the screen. (RED) (GAIN) (CUT OFF) ** e.g. 70 (GREEN) ** ** (BLUE) ** **
i. Using cross hatch pattern set the G2 so that the display in the Red cut off box reads between 60 and 80 as above. NB. When adjusting the grey scale, the figures displayed in the boxes are an indication of the CRT�s performance only. The data to be adjusted is contained in the box at the bottom right corner of the picture. ii. Select a grey scale signal, then set the Red Cut-off level to 32 and the Red-Gain to 50. iii.Leave the Red Cut-off and Gain as above and adjust Green and Blue Cut-off and Gain to achieve correct grey scale tracking. As with all grey scale adjustments it will be necessary to readjust the settings to achieve good tracking. Changing NVM Data To change the data contained within the Non Volatile Memory, it is necessary to first select the page the data is stored in, then the position and finally to change the data itself. The procedure below outlines this process. 1. While on ALTER NVM PAGE, use the volume up/down buttons to change this data (data is shown in hexadecimal format). 2. Press the channel up button and ALTER NVM POSITION appears, use the volume up/down buttons to change this data (data is shown in hexadecimal format). 3. Press the channel up button and ALTER NVM VALUE appears, use the volume up/down buttons to change this data (data is shown in hexadecimal format). 4. Once this data has been set, press the standby button to store. 5. If another NVM value has to be changed, use the channel down button to select the page or position and repeat as necessary. Note: DO NOT change any NVM data, unless you have been advised to do so by a Sharp representative. If data is incorrectly changed, serious damage may occur to the receiver.
Contrast Adjustments Three types of contrast levels can be varied as listed below: � TELETEXT MIX MODE CONTRAST � TELETEXT CONTRAST � OSD CONTRAST Use the volume up/down buttons to adjust to a suitable level, then press the standby button to store.
9
|
|
|
> |
|