�MW / LW ADJUSTMENT� � For MW / LW adjustment, do wiring and connection as in the following.
60cm
Standerd Signal Generaor
SET TP Lch Rch GND
Connect to the respective measuring equipment
�� IF ADJUSTMENT (MW) Requirement Measuring equipment: Oscilloscope or Millivoltmeter Test point: TP7 (IC771 24pin), GND Adjustment point: L772 (1) Adjust the setting of Standard Signal Generator (hereinafter S.S.G.) to 450KHz of 30� variation. (2) While looking at the waveform on the oscilloscope, reduce the output level all the way. (3) Adjust L772 until the waveform of the oscilloscope reaches the maximum.
OSCILLOSCOPE
Lch Rch GND
CH1
CH2
GND
�� TRACKING ADJUSTMENT (MW) Requirement Measuring equipment: Millivoltmeter Test point: TP2, TP3, GND Adjustment point: L773 (1) Adjust the S.S.G. setting to 1000KHz of 30% variation and reduce the output level all the way. (2) Adjust the reception frequency of the main unit to 1000KHz. (3) Adjust L773 until the value of the millivoltmeter reaches the maximum.
AC MILLIVOLTMETER
TP2
GND
CH1
CH2
GND
TP3
�� TRACKING ADJUSTMENT (LW) Requirement AC MILLIVOLTMETER Measuring equipment: Millivoltmeter Test point: TP2, TP3, GND Adjustment point: TC941, L941 TP2 CH1 CH2 (1) Adjust the S.S.G. setting to 290KHz of 30% variation and reduce the output level all GND the way. GND (2) Adjust the reception frequency of the main unit to 290KHz. TP3 (3) Adjust LTC941 until the value of the millivoltmeter reaches the maximum. (4) Adjust the S.S.G. setting to 144KHz of 30% variation and reduce the output level all the way (5) Adjust the reception frequency of the main unit to 144KHz (6) Adjust LTC941 until the value of the millivoltmeter reaches the maximum. (7) Repeat the adjustment 2 to 3 times from 1 to 6 above.
-29-
|
|
|
> |
|