|
Usuarios conectados
Actualmente hay 5692 visitantes online.
|
Productos
|
Información
|
Destacado
|
|
|
|
|
No hay comentarios de productos.
Major Operating Controls and Their Functions
LOCK OPEN
Hole for microphone cable
Ceiling Mount Bracket
Notch for network cable, monitor output cable, etc. Microphone stand*
Operating Instructions
Model Nos.
WV-Q152C WV-Q152S
Ceiling mount bracket
Dome cover
Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. No model number suffix is shown in this manual.
* If a microphone is used, mount the microphone on the rubber-made microphone stand. Unless the microphone is used, cut the rubber with a nipper or conduct another treatment.
<For using the direct ceiling mount bracket for the camera, WV-Q105>
NM0806-1096 3TR004562BAA Printed in Japan
WV-Q105 (option) Anchor bolt (Procured locally) Safety wire angle (WV-Q105 supplied) Ceiling board such as plaster board Mounting screws (4 pcs.) WV-Q105 supplied)
Preface
This bracket is exclusively designed to mount the network camera, DG-NS202, on a wall. The network camera shall be mounted on this bracket after mounting this bracket on a ceiling. � WV-Q152C: Clear dome cover � WV-Q152S: Smoked dome cover (approx. 50 % of transmittance)
Safety wire (WV-Q105 supplied)
Ceiling mount bracket
Inner shell
Precautions
� Refer installation work to the dealer. Installation work requires technique and experiences. Failure to observe this may cause fire, electric shock, injury, or damage to the product. Be sure to consult the dealer. � Use only the specified camera. Failure to observe this may cause a fall of an inappropriate camera resulting in injury or accidents. Mount WV-NS202 on this bracket exclusively. � Avoid installing this bracket in the locations where salt damage occurs or corrosive gas is produced. Otherwise, the mounting portions will deteriorate and accidents such as a fall of the camera may occur. � The screws and fixation mechanisms shall be tightened securely. Failure to observe this may cause a fall of the camera resulting in injury. � Select an installation area that can support the total weight. If a selected area is too weak to support the total weight, a fall of the product may occur resulting in injury. Installation work shall be started after sufficient reinforcement. � Periodic inspections shall be conducted. Rust on the metal parts or screws may cause a fall of the product resulting in injury. Consult the dealer for the inspections. � The measures of protection against a fall of the camera shall be taken. Failure to observe this may cause injury. Be sure to install the safety wire. � Do not rub the edges of metal parts with your hand. Failure to observe this may cause injury. � Make sure that the installation area is strong enough to hold the total weight of the camera assembly (approx. 1.2 kg {2.6 lbs.}) before installation. � The pull-out strength of the installation area shall be 196 N {20 kgf} or more per 1 screw. If a ceiling board such as plaster board is too weak to support the total weight, the area shall be sufficiently reinforced or the optional direct ceiling mount bracket for the camera, WV-Q105, shall be used. � Procure 4 screws (M4 or M6) securing the camera mounting bracket (supplied with the camera) according to the material of the installation area. In this case, wood screws and nails should not be used. For mounting a camera on a concrete wall, use an anchor bolt (for M6) or an AY plug bolt (M4 or M6) manufactured by Matsushita Electric Works, Ltd. for securing. (Recommended tightening torque M4: 1.6 N·m {16 kgf·cm}, M6: 5.0 N·m {51 kgf·cm}) � Avoid installing in the following locations. � Locations where it may get wet from rain or water splash (not only outdoor) � Locations where a chemical agent is used such as a swimming pool � Locations subject to steam and oil smoke such as a kitchen � Locations where radiation or x-ray emissions are produced � Locations where it may be damaged by briny air such as seashores � Locations where the temperature is not within �10 °C - +50 °C {14 °F- 122 °F}. � Locations subject to vibrations (This product is not designed for on-vehicle use.) � Locations where the temperature may rapidly change such as the peripheral areas of the air outlets of air conditioners or doors facing outside. (In case of installing the camera in such locations, the dome cover may become foggy or condensation may be caused on the cover.) � The screws and bolts must be tightened with an appropriate tightening torque according to the material and strength of the installation area. After tightening the screws or bolts, perform visual check to ensure tightening is enough and there is no backlash. � The protection sheet attached to the dome cover shall be peeled off after installation.
Dome cover
Installations
Be sure to read "Precautions" before installation. The Installation Guide of the network camera, WVNS202, shall be read as well. 1. Install the inner shell. Slide the covers located on the both lateral sides of the camera and put the inner shell on the camera until the hooks inside the inner shell are held in the holes of the camera (until a click is heard). Important: Put the inner shell down on the camera until the outside cover of the camera cannot be seen from the opening (from which the camera lens is visible) of the inner shell. If this integration is not successfully performed, the inner shell may be removed or the hidden part at the top of the screen may become larger in the WIDE mode.
Hook Put on until a click is heard Cover Inner shells
How to remove the inner shell Press the inner shell from the front and rear sides inward (at the same vertical position as the hooks) to bend the shell and remove the shell from the camera.
Press from the front and rear sides inward to bend
(To be continued reverse page)
|
|
|
> |
|