3-2. MECHANISM ADJUSTMENT (RIGHT POSITION ADJUSTMENT OF CAMERA)
Procedure of right position adjustment of camera is as follows. 1. Set the camera to WIDE and check that when the monitor is displayed, the left and rights sides of the backlight frame on the table are equal. If the backlight frame is not egualed: 2. Remove the five screws (B2.6x6), then remove the case A, B.
Case A
screw (B2.6x6)
Case B screw (B2.6x6)
screw (B2.6x6)
3. Loosen the two step screws. (Caution : Never remove the two screws) The camera is tilted and the left side of the table appears on the monitor screen. 4. Tighten the two step screws loosen at step 3 at the position that the right or left shift of the backlight frame on the table is eliminated.