NO.13 FLOW CHART NO.15
The drum motor fails to run. No head switching pulse.
Is the voltage more than about 2.6V Is the drum motor rotating? NO Check IC701. See FLOW CHART NO.13,14. DC given out pin(46) of IC701.
YES
Is the PG signal and drum FG NO Are there drum PG M.M.signal at Is the supply voltage of 5V feed to Check PC 5V line. signal present on pins(66) and (65) pin(81) of IC701? pin(3) of IC706? of IC701, respectively?
YES NO
YES NO Check between pin(46) of IC701 Is the voltage more than about 2.6V
YES
Check C723 and readjust R724. applied at pin(2) of IC706? IC706. (HEAD SW. POINT control.) and all the way up to pin(2) of
YES Replace IC701. NO
Is the supply voltage of feed to Check AT 12V line. pin(21) of IC706? Are the PG and drum FG YES Could be lines between IC706 signals present on pins(7) and (8) of
NO
IC706? Check peripheral circuit of IC706.
and IC701. YES
Check or replace drum motor.
FLOW CHART NO.14
42
Replace IC706.
NO
The drum motor runs only for a few seconds.
Is drum PG signal given out NO Check pin(4), (5), (6) of IC706 and pin(7) of IC706? periperal circuits.
YES
Check or replace drum motor.
Is drum PG signal given out of
pin(66) of IC701?
Check line between pin(7) of IC706 NO and all the way up thru to pin(66) of IC701.