Su carrito de compras está vacío
 
English Polski Spanish 
Buscar un manual
 

(p.Ej. AA-V20EG JVC, ZX-7 Sony)
PayPal 1000+ rating Secure, Encrypted Checkout.
 
Usuarios conectados
Actualmente hay 6043 visitantes online.
Productos
Información
Destacado
Inicio >> SHARP >> UXB700 Manual de Servicio
 
 0 artículo(s) en Su carrito 

SHARP UXB700
Manual de Servicio


¡Twitee acerca de este producto y obtenga $1.00 de crédito en la tienda para uso!
  • Contiene diagramas del circuito
  • Descargable
  • Formato PDF
  • Manual completo
  • Idiomas: English
Precio: $4.99

Descripción del SHARP UXB700 Manual de Servicio

Manual de servicio completo en formato digital (archivo PDF). Los manuales de servicio por lo general contienen diagramas de circuitos, tarjetas de circuitos impresos, consejos para reparación, diagramas de cableado, diagramas de bloque y lista de refacciones. El Manual de Servicio (a veces llamado Manual de Reparación) es usado principalmente por los técnicos.

Si tan solo quiere saber cómo utilizar su televisión, reproductor de vídeo, reproductor de mp3, etc. Quizá lo que necesita es el Manual del Propietario. Después de colocar la orden le enviaremos las instrucciones de descarga a su dirección de e-mail.

The manual is available in languages:

Not yet ready
You must purchase it first

Opiniones de los clientes
No hay comentarios de productos.

TEXT_PDF_SNIPPET
FO-B1600MY/SG/TH/ZA UX-B700TH
SW-B5 No. 6 ~ No. 8 Reserved Set to "0". SW-B6 No. 1 ~ No. 5 DTMF signal transmission level (High) The transmission level of DTMF signal is adjusted. (higher frequency) 00000: 0dBm � 11111: -15.5 dBm (-0.5dBm x 31) SW-B6 No. 6 ~ No. 8 Reserved Set to "0". SW-C1 No. 1, No. 2 Reading slice (Binary) Used to determine the set value of reading density in standard/fine mode. The standard setting is "00" (Factory setting is "00") SW-C1 No. 3, No. 4 Reading slice (Half tone) Used to determine the set value of reading density in half tone mode. The standard setting is "00" (Factory setting is "00") SW-C1 No. 5 Line density selection Used to set the transmission mode which is automatically selected when the Resolution key is not pressed. In the copy mode, however, the fine mode is automatically selected unless the Resolution key is manually set to another mode. SW-C1 No. 6 Reserved Set to "0". SW-C1 No. 7 MTF correction in half tone mode This allows selection of MTF correction (dimness correction) in the half tone mode. When "NO" (=1) is selected, the whole image becomes soft and mild. Clearness of characters will be reduced. Normally set to "YES" (=0). SW-C1 No. 8 Reserved Set to "0". SW-D1 No. 1 ~ No. 4 Number of rings for auto receive When the machine is set in the auto receive mode, the number of rings before answering can be selected. It may be set from one to four rings using a binary number. Since the facsimile telephone could be used as an ordinary telephone if the handset is taken off the hook, it should be programmed to the user�s choice. If the soft switch was set to 1, direct connection is made to the facsimile. If a facsimile calling beep was heard when the handset is taken off the hook, press the START key and put the handset on the hook to have the facsimile start receiving. If it was set to 0 accidentally, receive ring is set to 1. NOTE: If the machine is set to answer after a large number of rings, it may not be able to receive faxes successfully. If you have difficulty receiving faxes, reduce the number of rings to a maximum of 6. SW-D1 No. 5 Automatic switching manual to auto receive This soft switch is used to select whether the machine should switch to the auto receive mode after 5 rings in the manual receive mode or remain in the same way as SW-D1 No. 1, No. 2, No. 3 and No. 4 "0"1"0"0"(5 rings). SW-D1 No. 6 Reserved Set to "0". SW-D1 No. 7, No. 8 CI detect frequency Detection frequency of ring signal for auto reception is set. When set to No. 7=0, No. 8=0, frequency is set to PTT recommendation. When set to No. 7=0, No. 8=1, frequency is set to 11.5Hz or more. When set to No. 7=1, No. 8=0, frequency is set to 13.0Hz or more. When set to No. 7=1, No. 8=1, frequency is set to 20.0Hz or more. SW-D2 No. 1 ~ No. 4 Reserved Set to "0". SW-E1 No. 6 Pseudo ringer ON/OFF cycle When set to "0", pseudo ringer is 1 sec ON and 2 sec OFF cycles. When set to "1", pseudo ringer is 1 sec ON and 4 sec OFF cycles. SW-E1 No. 7 Post answer tone (TEL/FAX mode) When set to "0", machine send the tones in TEL/FAX auto changeover mode. 01110 (50ms ~ 14): 700ms (CI interruption>700ms:Judged as a CI OFF section) The section 1 is not judged as a CI OFF section, the CI signal A is counted as one signal. The section 2 is judged as a CI OFF section, the CI signal B is considered as the second signal. 00111 (50ms ~ 7): 350ms (CI interruption>350ms:Judged as a CI OFF section) The section 1 is judged as a CI OFF section, and the CI signal A is counted as two signals. The section 2 is judged as a CI OFF section, and the CI signal B is considered as the third signal. SW-D3 No. 6 ~ No. 8 Reserved Set to "0". SW-E1 No. 1 TEL/FAX Automatic switching mode Used to set auto TEL/FAX switching mode or to set the normal fax mode. SW-E1 No. 2, No. 3 Pseudo ringing time at the TEL/FAX automatic switching mode Choice is made as to how long to rumble the dummy ringer on TEL/FAX automatic switching mode. SW-E1 No. 4 Number of CNG signal detection at the TEL/FAX automatic switching mode Used for detection of CNG in one or two tones in the TEL/FAX automatic switching mode. SW-E1 No. 5 CNG detection when TEL/FAX mode The switch which sets the time from the start of CNG detection to the end of detection. SW-D2 No. 5 Caller ID function (FO-B1600MY/SG) Used for Caller ID function. SW-D2 No. 6 Caller ID detect during CI off (FO-B1600MY/SG) Detection of caller ID signal is performed as follows: 0:First CI OFF only 1:All of CI OFF SW-D2 No. 5,No. 6 Reserved (UX-B700TH/FO-B1600TH/ZA) Set to "0". SW-D2 No. 7,No. 8 Reserved Set to "0". SW-D3 No. 1 ~ No. 5 CI off detection timer (0-1550ms setting by 50ms step) Set the minimum time period of CI signal interruption which affords to be judged as a CI OFF section with 50ms steps. (Example)

A

B

400msec
1

2000msec
2

2 � 21

Quizás también quiera comprar

$4.99

UXB700 SHARP
Manual de Usuario

Manual del propietario completo en formato digital. El manual estará disponible para descarga como …
>
Parse Time: 0.179 - Number of Queries: 110 - Query Time: 0.043