TX-2100 ADJUSTMENT AND CONFIRMATION PROCEDURES 1
Idling current adjustment Before Idling adjustment, turn the trimming resistors R533 and R534 to counter clockwise. Connect the DC voltmeter to terminals P521 and P522. After turn POWER to ON, adjust the trimming resistors R533 and R534 so that the reading of voltmeter becomes 2.0 mV. After adjustment, attach the top cover. Confirm the voltage of points above after about five minutes. When less than 7.0 mV, readjust the resistors above so that the voltage becomes 7.0 mV. When 7.0 mV to 9.0 mV, you are not necessary to adjust. When more than 9.0 mV, readjust the resistors above so that the voltage becomes 9.0 mV.
RIGHT VCT
NCAR-5864
P211a
P613a
P522
R534
R533 L-IID 30 P711a 1
IID
IID
VCT P521 LEFT
Confirmation of protection circuit 1. Confirmation of operation of speaker relay Confirm that the speaker relays turn ON approximate. 5 seconds after the power switch is turned ON. Confirm that the speaker relays turn OFF immediately after the power switch is turned OFF. 2. Confirmation of DC detection circuit Press and hold down CD button, then press DIRECT TUNING button. After "TEST- " on the FL tube light on, press TAPE 1 button to set the unit to "TEST-1 00". Apply DC 1.5 to 3V to CD terminal with no load. Confirm that the speaker relay turns OFF. Apply DC -1.5 to -3V to CD terminal with no load. Confirm that the speaker relay turns OFF. Caution: Don't apply DC voltage more than 1 sec..