Su carrito de compras está vacío
 
English Polski Spanish 
Buscar un manual
 

(p.Ej. AA-V20EG JVC, ZX-7 Sony)
PayPal 1000+ rating Secure, Encrypted Checkout.
 
Usuarios conectados
Actualmente hay 6034 visitantes y 
4 usuarios online.
Productos
Información
Destacado
Inicio >> ERICSSON >> T20 Manual de Servicio
 
 0 artículo(s) en Su carrito 

ERICSSON T20
Manual de Servicio


¡Twitee acerca de este producto y obtenga $1.00 de crédito en la tienda para uso!
  • Contiene diagramas del circuito
  • Descargable
  • Formato PDF
  • Manual completo
  • Idiomas: English
Precio: $4.99

Descripción del ERICSSON T20 Manual de Servicio

Manual de servicio completo en formato digital (archivo PDF). Los manuales de servicio por lo general contienen diagramas de circuitos, tarjetas de circuitos impresos, consejos para reparación, diagramas de cableado, diagramas de bloque y lista de refacciones. El Manual de Servicio (a veces llamado Manual de Reparación) es usado principalmente por los técnicos.

Si tan solo quiere saber cómo utilizar su televisión, reproductor de vídeo, reproductor de mp3, etc. Quizá lo que necesita es el Manual del Propietario. Después de colocar la orden le enviaremos las instrucciones de descarga a su dirección de e-mail.

The manual is available in languages: English

Not yet ready
You must purchase it first

Opiniones de los clientes
No hay comentarios de productos.

TEXT_PDF_SNIPPET
Trouble Shooting Guide, Advanced

With a Spectrum Analyser it is possible to catch a narrow sample of the spectrum as a time waveform due to a transmitted burst. By repeating that sample for a long raw of consecutive bursts it will be possible to measure the average of the spectrum components selected, in a time-gated measurement. The example of such a time waveform is seen in Fig. 4.5.

dB

Max-hold level = peak of switching transients

Switching transients Video average level = spectrum due to modulation

0%

50% midamble Averaging period Useful part of the burst

90% 100%

t

Fig. 4.5 In this time are visible waveform spectrum components from both the switching and the modulation. Looking at the time axis we know that the transmitter is started before the useful burst at the upramp. At that part of the waveform the spectrum is still affected by the upramp and a peak of switching transients is visible. The beginning of the time waveform is therefor not good for measuring the modulation spectrum. In the middle of the burst there is a training sequence, usually called midamble, with an equal bit pattern in every normal burst. This part is not interesting for modulation measurements either. The part of the waveform that follows after the midamble, called the Averaging period is the part decided to be measured as the Spectrum due to the Modulation and wide band noise by definition in the GSM spec. This period is finished at 90%, before the end of the burst. This is to avoid interference from switching transients at the downramp. At the end of the time waveform again spectrum components from the switching is present, because the time gated measurement has got a STOP point at the end of the downramp period.

4/00021-3/FEA 309 544/42 C © Ericsson Mobile Communications AB

32(38)

Quizás también quiera comprar

$4.99

T20 ERICSSON
Manual del propietario

Es una guía completa (también conocida como Manual de Operación o Manual del Propietario), y est�…
>
Parse Time: 0.241 - Number of Queries: 102 - Query Time: 0.053