� Adjustment Software CCB_SSC Control (J-6431-340-A) � Flange Back Adjustment Chart Join together a piece of white A0 size paper (1189 mm � 841 mm) and a piece of black paper to make the chart shown below.
4-1-2. Connection for Adjustment
IO-164 Harness 8P Pattern box (PTB-500) JIG BOARD CN10(8P) RS232C Personal Computer
CAMERA IFBoard CN602 AC 24V AC 24V Power Supply
White BLACK 841mm
PR-230 Board CN201
VIDEO OUT
Waveform monitor Relay jig (J-6430-530-A) J901
1189mm
Note:
Use a non-reflecting and non-glazing vellum paper. The size must be A0 or larger and the joint between the white and black paper must not have any undulations.
Adjustment Commander (J-6082-053-B) B/W monitor
� ND Filter ND25 (25%) 50 by 50 mm square, made by Kenko Make the transmission factor to 6.25% with double ND filter. � Oscilloscope � Frequency Counter � Digital Voltmeter � Waveform Monitor � B/W Monitor