Su carrito de compras está vacío
 
English Polski Spanish 
Buscar un manual
 

(p.Ej. AA-V20EG JVC, ZX-7 Sony)
PayPal 1000+ rating Secure, Encrypted Checkout.
 
Usuarios conectados
Actualmente hay 5475 visitantes online.
Productos
Información
Destacado
Inicio >> CASIO >> SPF51-1AV Manual de Usuario
 
 0 artículo(s) en Su carrito 

CASIO SPF51-1AV
Manual de Usuario


¡Twitee acerca de este producto y obtenga $1.00 de crédito en la tienda para uso!
  • Descargable
  • Formato PDF
  • Manual completo
  • Idiomas: English
Precio: $4.99

Descripción del CASIO SPF51-1AV Manual de Usuario

Manual del propietario completo en formato digital. El manual estará disponible para descarga como archivo PDF después de que lo compre.

El Manual del Propietario (a veces llamado Manual del Usuario o Guía del Usuario) contiene información sobre cómo utilizar su dispositivo. Después de colocar la orden le enviaremos las instrucciones de descarga a su dirección de e-mail.

The manual is available in languages: English

Not yet ready
You must purchase it first

Opiniones de los clientes
No hay comentarios de productos.

TEXT_PDF_SNIPPET
2345/2347-3
Using the barometric pressure graph
Barometric pressure is affected by changes in weather and temperature. The following shows how to interpret the data that appears on the barometric pressure graph. A rising graph generally means better weather.

THERMOMETER MODE
A built-in temperature sensor measures temperature and shows the measured value on the display. The thermometer can be calibrated to correct for errors. Important! Temperature measurements are affected by your body temperature (while you are wearing the watch), direct sunlight, and moisture. To achieve a more accurate temperature measurement, remove the watch from your wrist, place it in a well-ventilated location out of direct sunlight, and wipe off all moisture from the case. It takes approximately 20 to 30 minutes for the case of the watch to reach the temperature of the surrounding air.

A falling graph generally means deteriorating weather.

About temperature measurements
The watch takes temperature measurements every five seconds for the first two minutes after you enter the Thermometer Mode. The Thermometer Mode indicator 1 flashes on the display during these two minutes. After the first two minutes, the Thermometer Mode indicator 1 stops flashing, and the watch automatically takes measurements every five minutes.

Note that if there are sudden changes in weather or temperature, the graph line of past measurements may run off the top or bottom of the display. The entire graph will become visible once barometric pressure conditions stabilize.

Understanding the temperature display
The display shows �� � . � °C� (or °F) if a measured value falls outside the range of �10.0°C to 60.0°C (14.0°F to 140.0°F). The normal display will return as soon as the temperature returns within the allowable range.
Thermometer Mode indicator 1
A B

C

D

Selecting the unit of measurement
1. Use C to enter the Barometer Mode. 2. Hold down A until �OFF� or the current barometric pressure value flashes on the display. 3. Press C to change to the measurement unit selection screen. 4. Each press of D or B cycles the barometric pressure measurement unit as shown below.
hPa mb inHg
Remaining memory Thermometer Mode indicator 2

M

Temperature graph

Selecting the measurement unit
1. Use C to enter the Thermometer Mode. 2. Hold down A until �OFF� or the current temperature calibration value flashes on the display. 3. Press C to change to the measurement unit selection screen. 4. Each press of D or B toggles the temperature measurement unit as shown below.

5. After you select the measurement unit you want, press A to return to the Barometer Mode screen. � Note that all measurement data currently in memory is also deleted whenever you change the barometric pressure or temperature unit of measurement.

°C

M

°F

Calibrating the barometric pressure measurement
The sensor of this watch is calibrated at the factory before shipment, and further adjustment is normally not required. If noticeable error is found in the barometric pressure readings produced by the watch, you can adjust it to correct the error. Important! Incorrectly calibrating the barometric pressure measurement of this watch can result in incorrect readings. Compare the readings produced by the watch with those of another reliable, accurate barometer.

5. After you select the measurement unit you want, press A to return to the Thermometer Mode screen. � Note that all measurement data currently in memory is also deleted whenever you change the barometric pressure or temperature unit of measurement.

Calibrating the temperature measurement
The temperature sensor of this watch is calibrated at the factory before shipment, and further adjustment is normally not required. If noticeable error is found in the temperature readings produced by the watch, you can adjust it to correct the error. Important! Incorrectly calibrating the temperature measurement of this watch can result in incorrect readings. Carefully read the following before doing anything. � Compare the readings produced by the watch with those of another reliable, accurate thermometer. � If adjustment is required, remove the watch from your wrist and wait for 20 or 30 minutes to give the temperature of the watch time to stabilize.

To calibrate the barometric pressure
1. Use C to enter the Barometer Mode. 2. Hold down A until �OFF� or the current barometric pressure calibration value flashes on the display. � �OFF� appears when the factory setting is currently set as the current barometric pressure calibration value. 3. Each press of D increases the displayed barometric pressure by 1 hPa/mb, while pressing B decreases it. Holding down either button changes the value at high speed. � If inHg is currently selected as the unit of measurement, the above operations change the reading by 0.05 inHg. � Pressing B and D at the same time returns to the �OFF� setting. 4. After calibrating the barometric pressure, press A to return to the Barometer Mode screen.

To calibrate the temperature
1. Use C to enter the Thermometer Mode. 2. Hold down A until �OFF� or the current temperature calibration value flashes on the display. � �OFF� appears when the factory setting is currently set as the current temperature calibration value. 3. Each press of D increases the displayed temperature by 0.1°C, while pressing B decreases it. Holding down either button changes the value at high speed. � If Fahrenheit is currently selected as the unit of measurement, the above operations change the reading by 0.2°F. � Pressing B and D at the same time returns to the �OFF� setting. 4. After calibrating the temperature, press A to return to the Thermometer Mode screen.

M

The following conditions cause the barometric pressure measurement to be skipped, with the corresponding point on the barometric pressure graph being left blank. � Barometric reading that is out of range (460 hPa/mb to 1100 hPa/mb/13.55 inHg to 32.45 inHg). � Sensor malfunction. � Dead battery.

Temperature Unit of measurement

2 seconds later

Press A.

Quizás también quiera comprar

$4.99

SX-K700 TECHNICS
Manual de Usuario

Manual del propietario completo en formato digital. El manual estará disponible para descarga como …

$4.99

CJ-V51 PIONEER
Manual de Servicio

Manual de servicio completo en formato digital (archivo PDF). Los manuales de servicio por lo genera…

$4.99

GRAND PRIX ELECTRONIC 754 BECKER
Manual de Servicio

Manual de servicio completo en formato digital (archivo PDF). Los manuales de servicio por lo genera…

$4.99

SX-PR602 TECHNICS
Manual de Servicio

Manual de servicio completo en formato digital (archivo PDF). Los manuales de servicio por lo genera…

$4.99

EV-S1000E SONY
Manual de Usuario

Manual del propietario completo en formato digital. El manual estará disponible para descarga como …

$4.99

GRAND PRIX ELECTRONIC 780 BECKER
Manual de Servicio

Manual de servicio completo en formato digital (archivo PDF). Los manuales de servicio por lo genera…

$4.99

AG7330 PANASONIC
Manual de Servicio

Manual de servicio completo en formato digital (archivo PDF). Los manuales de servicio por lo genera…

$4.99

MECABLITZ 60 CT4 METZ
Manual de Servicio

Manual de servicio completo en formato digital (archivo PDF). Los manuales de servicio por lo genera…
>
Parse Time: 0.163 - Number of Queries: 129 - Query Time: 0.05