4.
CDM65-RBD2 Electrical Adjustment
4-1. Laser Power Adjustment 1) 2) Start up the TeraTermPro and set the switch S510 on the jig to �CONTROL�. Select the menu as follows. Control � Macro, and select 01ldp_S.ttl. Press �Open�. (Fig. 4-1)
4 Fig. 4-1
3) 4) 5)
Press the �RESET� button (SW101) of the jig as prompted by the display. Press the �RESET� button (SW101) of the jig again as prompted by the display. When the display as shown in Fig. 4-2 appears, type the serial number (see Fig. 4-3) that is printed on the label attached to the RBD2. (This dialog appears only when the EEPROM IC502 is replaced.)
4 Fig. 4-2
4 Fig. 4-3
When the display as shown in Fig. 4-4 appears, press �No�.
4 Fig. 4-4
When the display as shown in Fig. 4-5 appears after that, press �Yes�.
4 Fig. 4-5
38
|
|
 |
> |
|
|