Usuarios conectados
Actualmente hay 5047 visitantes online.
|
Productos
|
Información
|
Destacado
|
|
|
|
|
No hay comentarios de productos.
2. Insert the PC card in a personal computer. When the PC card is a good one, the �Signal strength� graph on the �Sony Wireless LAN Client Manager� screen changes from gray to green.
< Removing the PC card > 9. Double-click the �Unplug or Eject Hardware� icon.
Signal strength graph
Remarks: If the color does not change: � The main power of the access point is not turned on. � The PC card is defective.
Unplug or Eject Hardware icon
< Executing the card diagnosis > 3. Select �Advanced� � �Card diagnosis� on the �Sony Wireless LAN Client Manager� screen. 4. The diagnosis screen will appear. Click �Test card now�. Check that �OK� appears on all items.
10. The �Unplug or Eject Hardware� screen will appear. Select �Sony PCWA-C150Wireless PC Card� and click the �Stop� button.
Click
[Card Diagnosis screen]
5. Press the �Cancel� button to end the card diagnosis. 11. The �Safe to Remove Hardware� screen will appear. Select �Sony PCWA-C150Wireless PC Card� and click OK. The following message appears.
< Executing the LINK Test > 6. Select �Advanced� � �LINK Test� on the �Sony Wireless LAN Client Manager� screen. 7. The LINK Test screen will appear. Check �SNR� and �Signal level� in the �This station� and the �Test Partner�.
Select �OK� and remove the PC card.
End of inspection When you want to inspect other cards continuously, repeat steps 1 to 11 of section 1-3.
1-4. Procedure How To Identify the Error When the PC Card Is Defective.
Preparation: � Prepare the dummy antenna block. 1. Separate the card and antenna block. 2. Install the dummy antenna block to the card. 3. Perform inspection of steps 1 to 11 of item 1-3. 4. If the product works satisfactorily, the antenna block is diagnosed to be a good antenna block. 5. If the product does not work satisfactorily, the card block is defective.
[LINK Test screen]
Inspection criterion � The �SNR� gauge should light in green. If the �SNR� gauge lights in yellow, the equipment is diagnosed as defective. � The �Signal level� should be -55 dBm or more. 8. Press the �Cancel� button to end the inspection.
�5�
Confidential
|
|
|
> |
|