5. Put the REC MODE switch to the STANDARD 48k (ATF: ON) position and put the REMOTE switch to either the WIRED or WIRELESS position (OFFSET: � or +), then check the RF signal waveform.
Check that there is a difference of 650 ± 15 µsec between the oscilloscope�s SWP signal and the RF signal.
RF
4 A or less 5 NG A
650±15 µsec
SWP
Adjustment Location: See page 26.
4 A� or less 5 NG A'
OK
6. Put the REC MODE switch to the STANDARD 48k (AFT: ON) position and put the REMOTE switch to the OFF position (OFFSET: 0), then check the RF signal waveform. (1) Verify that the peak value (B) of the RF signal waveform is 60mV or more. (2) Verify that the flat position of the RF signal waveform has undershoots of 10% or less.
B or less 10 B or less 10 B
CHECK AND REPLACEMENT FOR DATE FNCTION Clock IC Back-up Check � When replacing the lithium battery (BATT501) or replacing any of the clock IC (IC518) and peripheral parts, the clock will be reset. (The DATE display will be [�-- -- --] [--h--m--s] even when the [PRESENT] button is pushed.) Perform the back-up check by the following procedure. (1) Connect a DC voltmeter between the DIGITAL board�s TP (BATT+) as (+) side on the TP (BATT�) as (�) side. (2) With the POWER switch of the set OFF, check that the voltage (1) is less than +20 mV. (If the measured value is more than +20 mV, inspect the IC518 and peripheral parts and replace as needed.) (3) With the POWER switch of the set ON, check that the voltage (1) is less than 0 mV (minus indication), (If plus indication, inspect the D510 and peripheral parts and replace as needed.) (4) When these voltages are normal, set the clock to the current date and time according to the instruction manual. (year/month/day/day of week/hours/minutes/seconds)* (5) After the clock is set in item (4), turn off the POWER switch once and in several seconds, turn on the power again and make sure that the clock is operating. Adjustment Location: See page 26.
7. If any of the specified values are not satisfied, repeat items 3 to 6. Adjustment Location: See page 23. DPG Adjustment When replacing any drum related parts, be sure to perform this adjustment. Adjustment Method: 1. Connect the CH-1 terminal of an oscilloscope to TP (RF) and the CH-2 terminal to TP (SWP) on the DIGITAL board. 2. Enter the Test Mode 1 (see page 22.) and set the test tape TY7252 (8-909-822-00). 3. Put the REC MODE switch to the STANDARD 48k (ATF: ON) position and put the REMOTE switch to the OFF position (OFFSET: 0). 4. Press the AMS (+) key. 5. Press the PLAY (�) key. 6. �DPG OK� is displayed in the fluorescent indicator tube.
� 25 �
|
|
|
> |
|