CAUTIONS: 1. Before starting-up the OXF-R3, check that all Monitor Loudspeaker Power Amps are turned off or muted. 2. Switch on equipment in the sequence given here, to ensure troublefree start-up.
2-1-1 Start-Up Procedure
1. Check that the motionworker and Lynx Time Code Module are already switched on and running normally. 2. Switch on the power to the SP Rack. 3. Switch on the power to the Host Computer. 4. Switch on the power to the I/O Racks.
Note:
Chapter 2 Powering The OXF-R3
It is important that the I/O racks are switched on in the sequence of the Sync Clock wiring loop connected to the clock inputs of the I/O Racks.
5. The Host Computer performs its start-up and self-test routines. At the end of these routines, a triple chevron prompt >>> should be displayed on the monitor. 6. Type b then press {RETURN} to start the boot-up process for the OXF-R3 system.
Note:
If your Host Computer has been configured for Auto-boot (an option at set-up), the triple chevron prompt will not be displayed and boot-up will proceed automatically.
7. At the end of the boot-up procedure, the Login field will be displayed on the monitor. 8. Now switch on the power to the control panel. All 7 LCD screens will show activity as programs are downloaded from the Host Computer to the computers within the console. When downloading is completed, an �X� is displayed in the centre of each screen.