4. Once left side has cleared, remove nozzle housing from motor shaft.
4. Replace motor support cover and motor case. Secure with four (4) screws that were removed earlier. 5. Reinstall dust cover as outlined in Dust Cover Removal and Replacement section.
3.6.
3.6.1.
Lower Plate Replacement
Removal
1. Place the Carpet/Bare Floor pedal in the carpet position and the handle in the upright position. 2. Turn the vacuum cleaner over exposing the underside. Release lower plate by pressing two (2) latches and two (2) locking tabs inward as shown.
3.5.2.
Installation
1. Fit the nozzle from the motor shaft side first, and rotate it into place on the dust container. 3. Remove the lower plate and remove any residue that may exist in the belt area.
3.6.2.
Installation
1. Reinstall lower plate by hooking front end of lower plate into slots on front of nozzle housing.
2. Rotate nozzle shaft into groove on dust container. 3. Place floor nozzle spring into slot on dust compartment.
2. Press lower plate until locking tabs snap into place then push the two (2) latches outward.