compartment. 2. Rewire per the Pictorial Diagram. 3. Replace the motor case and the four (4) screws. 4. Turn the vacuum back over and replace the plastic holder, thick side out, plastic shaft, light bulb assembly, nozzle housing, belt, agitator assembly, and lower plate according to the respective installation instructions. NOTE: For general servicing, it is necessary to eliminate pinching of any wire during reassembly. After servicing any electrical component or electrical enclosure, the unit should be reassembled and checked for dielectric breakdown or current leakage
3.7.2.
Installation
1. Reinstall the motor protector into the dust compartment by aligning the two tabs with the slots in the dust compartment by applying pressure from the back of the vacuum until it snaps into place.
3.8.
3.8.1.
Motor Replacement
Removal
1. Remove the dust cover by grasping the top near the on-off switch and pulling sharply out toward you.
2. Remove the lower plate, agitator assembly, belt, the plastic shaft, and the nozzle housing as instructed in the respective removal sections. 3. Turn the vacuum over to the front side. 4. Remove the four (4) screws from the motor case and then remove the motor case. 5. Disconnect the motor leads and remove the motor. Remove the motor support rubber (rear), noise suppressor, and the motor support rubber (front). Place these items on the new motor.
3.8.2.
Installation
1. Place the motor back into the dust compartment with brushes aligned parallel to the front edge of the dust