IUD6000SS0 Quantity: 1
$4.99
» View Details
25PT5207/60 Quantity: 1
$4.99
» View Details
FCE10500W Quantity: 1
$4.99
» View Details
AG-1980P Quantity: 1
$4.99
» View Details
GSN2000HZ0 Quantity: 1
$4.99
» View Details
GT1SHTXMQ01 Quantity: 1
$4.99
» View Details
490.723.4/40020 Quantity: 1
$4.99
» View Details
AT-90SL Quantity: 1
$4.99
» View Details
56510IW,10769 Quantity: 1
$4.99
» View Details
HT-SP904 Quantity: 1
$4.99
» View Details
HB 510 WF Quantity: 1
$4.99
» View Details
WERP3101SS1 Quantity: 1
$4.99
» View Details
RT18EKRXL02 Quantity: 1
$4.99
» View Details
TRKE 9097 Quantity: 1
$4.99
» View Details
190V6FB/27B Quantity: 1
$4.99
» View Details
TRIDENT Quantity: 1
$4.99
» View Details
ADG 673 FD Quantity: 1
$4.99
» View Details
SCF0710KQ01 Quantity: 1
$4.99
» View Details
ADG 7720 IX Quantity: 1
$4.99
» View Details
DVR-543H-S Quantity: 1
$4.99
» View Details
KSRS25ILWH00 Quantity: 1
$4.99
» View Details
DVD-V5450XEU Quantity: 1
$4.99
» View Details
Subtotal: $109.78
 
English Polski Spanish 
Buscar un manual
 

(p.Ej. AA-V20EG JVC, ZX-7 Sony)
PayPal 1000+ rating Secure, Encrypted Checkout.
 
Usuarios conectados
Actualmente hay 4907 visitantes online.
Productos
Información
Destacado
Inicio >> SONY >> KV32HS20 Manual de Servicio
 
 22 artículo(s) en Su carrito 

SONY KV32HS20
Manual de Servicio


¡Twitee acerca de este producto y obtenga $1.00 de crédito en la tienda para uso!
  • Contiene diagramas del circuito
  • Descargable
  • Formato PDF
  • Manual completo
  • Idiomas: English
Precio: $4.99

Descripción del SONY KV32HS20 Manual de Servicio

Manual de servicio completo en formato digital (archivo PDF). Los manuales de servicio por lo general contienen diagramas de circuitos, tarjetas de circuitos impresos, consejos para reparación, diagramas de cableado, diagramas de bloque y lista de refacciones. El Manual de Servicio (a veces llamado Manual de Reparación) es usado principalmente por los técnicos.

Si tan solo quiere saber cómo utilizar su televisión, reproductor de vídeo, reproductor de mp3, etc. Quizá lo que necesita es el Manual del Propietario. Después de colocar la orden le enviaremos las instrucciones de descarga a su dirección de e-mail.

The manual is available in languages: English

Not yet ready
You must purchase it first

Opiniones de los clientes
No hay comentarios de productos.

TEXT_PDF_SNIPPET
KV-32HS20/36HS20/36HS20H/32XBR450/36XBR450/36XBR450H

SAFETY CHECK-OUT
After correcting the original service problem, perform the following safety checks before releasing the set to the customer: 1. Check the area of your repair for unsoldered or poorly soldered connections. Check the entire board surface for solder splashes and bridges. 2. Check the interboard wiring to ensure that no wires are �pinched� or touching high-wattage resistors. 3. Check that all control knobs, shields, covers, ground straps, and mounting hardware have been replaced. Be absolutely certain that you have replaced all the insulators. 4. Look for unauthorized replacement parts, particularly transistors, that were installed during a previous repair. Point them out to the customer and recommend their replacement. 5. Look for parts which, though functioning, show obvious signs of deterioration. Point them out to the customer and recommend their replacement. 6. Check the line cords for cracks and abrasion. Recommend the replacement of any such line cord to the customer. 7. Check the B+ and HV to see if they are speci�ed values. Make sure your instruments are accurate; be suspicious of your HV meter if sets always have low HV. 8. Check the antenna terminals, metal trim, �metallized� knobs, screws, and all other exposed metal parts for AC leakage. Check leakage as described below. 3. Measuring the voltage drop across a resistor by means of a VOM or battery-operated AC voltmeter. The �limit� indication is 0.75 V, so analog meters must have an accurate low voltage scale. The Simpson�s 250 and Sanwa SH-63TRD are examples of passive VOMs that are suitable. Nearly all battery-operated digital multimeters that have a 2 VAC range are suitable (see Figure A). Leakage Test The AC leakage from any exposed metal part to earth ground and from all exposed metal parts to any exposed metal part having a return to chassis, must not exceed 0.5 mA (500 microamperes). Leakage current can be measured by any one of three methods. 1. A commercial leakage tester, such as the Simpson 229 or RCA WT-540A. Follow the manufacturers� instructions to use these instructions. 2. A battery-operated AC milliammeter. The Data Precision 245 digital multimeter is suitable for this job.

How to Find a Good Earth Ground A cold-water pipe is a guaranteed earth ground; the cover-plate retaining screw on most AC outlet boxes is also at earth ground. If the retaining screw is to be used as your earth ground, verify that it is at ground by measuring the resistance between it and a cold-water pipe with an ohmmeter. The reading should be zero ohms. If a cold-water pipe is not accessible, connect a 60- to 100-watt troublelight (not a neon lamp) between the hot side of the receptacle and the retaining screw. Try both slots, if necessary, to locate the hot side on the line; the lamp should light at normal brilliance if the screw is at ground potential (see Figure B).

To Exposed Metal Parts on Set
Trouble Light AC Outlet Box Ohmmeter

0.15 µF

1.5 k

AC Voltmeter (0.75V)
Cold Water Pipe

Earth Ground

Figure A. Using an AC voltmeter to check AC leakage.

Figure B. Checking for earth ground.

�5�

Quizás también quiera comprar

$4.99

KV-32HS20 SONY
Manual de Usuario

Manual del propietario completo en formato digital. El manual estará disponible para descarga como …
>
Parse Time: 0.186 - Number of Queries: 180 - Query Time: 0.055