PSLX410/C Quantity: 1
$4.99
» View Details
VB-2 Quantity: 1
$4.99
» View Details
KT-SR1000UJ Quantity: 1
$4.99
» View Details
GS2SHAXLB02 Quantity: 1
$4.99
» View Details
VC579E Quantity: 1
$4.99
» View Details
LW200D-3A Quantity: 1
$4.99
» View Details
SA5000 Quantity: 1
$4.99
» View Details
MB4010 Quantity: 1
$4.99
» View Details
GF4646HT/B Quantity: 1
$4.99
» View Details
MS510 Quantity: 1
$4.99
» View Details
LXW82-7510TOP Quantity: 1
$4.99
» View Details
AR8493B Quantity: 1
$4.99
» View Details
ED22DWXTW01 Quantity: 1
$4.99
» View Details
VC779E Quantity: 1
$4.99
» View Details
WAMP100H Quantity: 1
$4.99
» View Details
AV21LH Quantity: 1
$4.99
» View Details
GRAX470EE Quantity: 1
$4.99
» View Details
SC528L ANALOGUE Quantity: 1
$4.99
» View Details
PC36/3PTA Quantity: 1
$4.99
» View Details
KX-T7536LA-B Quantity: 1
$4.99
» View Details
MW24FM5 Quantity: 1
$4.99
» View Details
CM4536 Quantity: 1
$4.99
» View Details
C 313 BL Quantity: 1
$4.99
» View Details
ST3L/K Quantity: 1
$4.99
» View Details
S400 Quantity: 1
$4.99
» View Details
KGYE664WAL0 Quantity: 1
$4.99
» View Details
KEHP4500R Quantity: 1
$4.99
» View Details
GC3NHAXSQ00 Quantity: 1
$4.99
» View Details
ST191CC Quantity: 1
$4.99
» View Details
20PF5120/98 Quantity: 1
$4.99
» View Details
Subtotal: $149.70
 
English Polski Spanish 
Buscar un manual
 

(p.Ej. AA-V20EG JVC, ZX-7 Sony)
PayPal 1000+ rating Secure, Encrypted Checkout.
 
Productos
Información
Destacado
Inicio >> KENWOOD >> KDC-X8529 Manual de Servicio
 
 30 artículo(s) en Su carrito 

KENWOOD KDC-X8529
Manual de Servicio


¡Twitee acerca de este producto y obtenga $1.00 de crédito en la tienda para uso!
  • Contiene diagramas del circuito
  • Descargable
  • Formato PDF
  • Manual completo
  • Idiomas: English
Precio: $4.99

Descripción del KENWOOD KDC-X8529 Manual de Servicio

Manual de servicio completo en formato digital (archivo PDF). Los manuales de servicio por lo general contienen diagramas de circuitos, tarjetas de circuitos impresos, consejos para reparación, diagramas de cableado, diagramas de bloque y lista de refacciones. El Manual de Servicio (a veces llamado Manual de Reparación) es usado principalmente por los técnicos.

Si tan solo quiere saber cómo utilizar su televisión, reproductor de vídeo, reproductor de mp3, etc. Quizá lo que necesita es el Manual del Propietario. Después de colocar la orden le enviaremos las instrucciones de descarga a su dirección de e-mail.

The manual is available in languages: English

Not yet ready
You must purchase it first

Opiniones de los clientes
No hay comentarios de productos.

TEXT_PDF_SNIPPET
KDC-MP828/W7531/W7531Y/W8531 /W8531Y/X789/X8529/X889

TEST MODE
2. When entering the test mode, the manufacture code of the Flash ROM (4M) is read and when it is normal, FROMCHK of the 100th terminal (Panel µ-com) repeats Hi � Low � Hi · · ·. If the reading is abnormal, �Low� is output. If the manufacture code is normal, by pressing [ ] key for less than 1 second, the connection checks on all terminal is started. If the connections are normal, the FROMCHK terminal stops the Hi � Low � Hi · · · repeating and outputs �Hi�. If the reading is abnormal, �Low� is output. 3. With all lights turned on and by pressing [AM] key for at least 1 second, the data on the Flash ROM (4M) is initialized. While erasing the data, �Data_Erase....� is displayed. Note : Do not touch any key white this is in progress. When erasing is complete, �Erase_OK!!� is displayed. If �Erase_NG!!!!!!� is displayed, it was not possible to erase the data on the Flash ROM (4M). In this case, pressing [AM] key for at least 1 second again. If it is the same, then there is an abnormality with the Flash ROM. � While in the test mode, and at the same time, PM_DET of the 60th terminal (System µ-com) is H, the following will apply to the EJECT key, regardless of whether a disc is in the unit or not. Panel full OPEN/CLOSE is conducted with a push for less than 1 second. (Protection time : 3 seconds) As far as this item is concerned, eject will be achieved by for at least 1 second push on the EJECT key.

� Clearing backup memory and installer memory data (Clearing E2PROM data)
1. By pressing [ ] (NEXT) key and [ATT] key simultaneously, reset and start the unit. This will start the initialization processes for backup and installer memory data and the error log information of the CD mechanism. 2. When initialization is complete, the following display will be made. Normal completion CD_E2P___: AUDIO_E2P:

� Other
� At Power ON, �CODE_OFF�, �CODE_ON� displays will not be made. � When sourcing STANDBY, by pressing [AUTO] or [TI] key for less than 1 second, GREEN/RED of the key illumination is switched. When doing this, the triangle illumination GREEN/RED is switched along with the key illumination. � When staring up in the test mode, LINE MUTE prohibition time is set to 1 second instead of 10 seconds. � While in the test mode, even when a DC offset error is detected, the detection information will not be written to the E2PROM. � While in the test mode, even after an elapse of pre-set time, the backup memory items will not be written to the E2PROM. � Information Clear mode for Test Mode, backup/installer memory, and CD mechanism error log. In the DC offset error detection information clear mode, DEMO mode operation will not be conducted. Also, in the above mode, the menu of the STANDBY source will not display DEMO ON/OFF switching items.

Abnormal ending 1 : backup/installer memory initialization : NG CD_E2P___: AUDIO_E2P:

Abnormal ending 2 : CD mechanism error log initialization : NG CD_E2P___: AUDIO_E2P:

Abnormal ending 3 : All initialization : NG CD_E2P___: AUDIO_E2P:

3. While in this mode, even after an elapse of a pre-set time, no backup memory items will be written to the E2PROM. 4. This mode is released by resetting. (What was on the last screen will not be retained.)

16

Quizás también quiera comprar

$4.99

KDC-X8529 KENWOOD
Manual de Usuario

Manual del propietario completo en formato digital. El manual estará disponible para descarga como …
>
Parse Time: 1.26 - Number of Queries: 218 - Query Time: 0.718