CD SECTION
Note: 1. CD Block is basically designed to operate without adjustment. Therefore, check each item in order given. 2. Use YEDS-18 disc (3-702-101-01) unless otherwise indicated. 3. Use an oscilloscope with more than 10 M� impedance. 4. Clean the object lens by an applicator with neutral detergent when the signal level is low than specified value with the following checks.
Procedure : 1. Connect oscilloscpe to TP (TE) and TP (VC). 2. Turn the power ON. 3. Load a disc (YEDS-18) and playback the number five track. 4. Press the ^ (CD) button. (Becomes the 1 track jump mode) 5. Confirm that the level B and A (DC voltage) on the oscilloscope waveform.
1 track jump waveform
Procedure: 1. Connect oscilloscope to TP (FE). Connect between TP (FE1) and TP (VC) by lead wire. Connect between TP (AGCCON) and TP (GND) by lead wire. Turn the power ON. Load a disc (YEDS-18) and actuate the focus search. (In consequence of open and close the disc tray, actuate the focus search) 6. Cofirm that the oscilloscope waveform (S-curve) is symmetrical between A and B. And confirm peak to peak level within 4 ± 1 Vp-p.
S-curve waveform
symmetry
2. 3. 4. 5.
center of waveform B
Procedure: 1. Connect the frequency counter to check point of the VIDEO board. 2. Turned power switch on. 3. Press the FUNCTION button to select the CD. 4. Adjust CT503 on the VIDEO board so that the frequency counter reading 27.0 MHz ± 80 Hz at stop status. Adjustment Location:
0V
A (DC voltage)
VIDEO Board (SIDE B)
level = 1.3 ± 0.6 Vp-p
symmetry
A Specified level: B � 100 = less than ± 22%
6. After check, remove the lead wire connected in step 1.
A within 4 ± 1 Vp-p B
7. After check, remove the lead wire connected in step 2 and 3.
Note: � Try to measure several times to make sure than the ratio of A : B or B : A is more than 10 : 7. � Take sweep time as long as possible and light up the brightness to obtain best waveform.
CT503 31 VIDEO Frequency Check point Adjustment (27 MHz) 50
IC505
Procedure: 1. Connect oscilloscope to TP (RF). 2. Connect between TP (AGCCON) and TP (GND) by lead wire. 3. Turn the power ON. 4. Load a disc (YEDS-18) and press the ^ button to play. 5. Confirm that the oscilloscope waveform is clear and check RF signal level is correct or not. 6. After check, remove the lead wire connected in step 2.
Note: Clear RF signal waveform means that the shape ��� can be clearly distinguished at the center of the waveform.