3.1.4 INSPECTION (FAULT ANALYSIS PROGRAM) METHOD
Caution: Please use in the Real MS-DOS mode. (The program does not work in the MS-DOS prompt (DOS window) of the Windows.)
A
� Discs to be used
CD-ROM DVD-ROM (Single) DVD-ROM (Dual) CD-R CD-RW DVD-R DVD-RW DVD+R DVD+RW : GGV1054 : GGV1035 : GGV1036 : GGX1011 : GGV1088 : GGV1049 : GGV1050 : RICHO : RICHO
B
� Inspection program disc
FA Program Disc: GGS1049
� Installation method
1. Copy the program file "R6a_fa.exe" .
� Execution method
1. Start the PC in the MS-DOS mode. 2. Move to the directory to which the program file has been copied. Example: CD DVR106 [enter] (For "C:\DVR106") 3. Execute the program. r6a_fa /sv [enter] : (in case of the Japanese environment) r6a_fa /e /sv [enter] : (in case of the English environment) (In case of English environment, it is difficult to see the frame line if command "/e" is not added.) Operation
To move the window To select the measurement item To execute the measurement To execute all items continuously To quit the program To format CD-RW (full) To format DVD-RW (quickl) To format DVD+RW (Basic)
C
Key Operation
Right or left cursor keys Up or down cursor keys Enter key Space key Esc key F or f key G or g key M or m key
D
� Start-up screen
DVR-106 (ATAPI) for FA (GGS1049) Ver1.1