|
Usuarios conectados
Actualmente hay 5831 visitantes online.
|
Productos
|
Información
|
Destacado
|
|
|
|
|
No hay comentarios de productos.
1
2
3
4
4. MODEL SETTING
A
� The Setup is Necessary When : a) When the MAIN Assy is replaced b) When the JCKB Assy is replaced c) When the MAIN Assy and JCKB Assy are replaced
Note : Make sure of setting the correct number.
� How to Setup the Model (RFXU type) 1) After power on, the following screen is displayed on TV monitor. Press " 41 " for DVR-320 by using the remote control unit for service(GGF1381).
[ Recorder 's Model Setting] Input the number by using the remote for Service. > -B Input No. [ 41 Model : DVR-320 ]
2) After 1), the following screen is displayed on TV monitor. Press " 043 " by using the remote control unit for service.
[ Recorder 's Type Setting] Input the number by using the remote for Service. > --C Input No. [ 02 [ 03 [ 04 : : : Type RD/RD <South America> ] RD/RA <PX> ] LF <Taiwan> ] (Type -- , Region No. -)
D
The setting complete when OSD is disappeared. 3) Unplug the power cable. 4) Reset the recorder to all its factory settings. 1. Make sure that the recorder is on. 2. Press and hold [STOP] and press [STANDBY/ON] key on the front panel. The recorder turns off with all settings reset. 5) Enter the Service Mode and then confirm the Model Name " DVR-320/LF ". 1. Make sure that the recorder is on. 2. Press [ESC] then [DISP] keys by using the remote control unit for Service.
DVR-320/LF VERSION : 4.� � SYSCON : RELEASE_44 Rev :1.3599.2.2 TUFLCON : 4.04 MASK DRIVE : DVD-RW DVR-107R 1.06 DADL000219WL
$ OK OK OK OK
E
DEVICE REGION C FLASH
: : : :
PRISM-PLUS 3 ��������� 32M
6) Escape the Service Mode. Press [ESC]. 7) Download the latest firmware. At last, the download is necessary to update the firmware of each ASSY. Refer to how to download using disc described to page 70 on the service manual RRV2925. Notes : 1) After the setting complete, you can NOT CLEAR the setting data. Make sure the pressing number. 2) " NG " is appeared on TV when unsuitable number is pressed. In such a case, please unplug the power cable and plug it again. Then restart the model setting. 8
1 2
F
DVR-320-S
3 4
|
|
|
> |
|