DTM-5.3 SERVICE PROCEDURES
1. Replacing the fuses
This symbol located near the fuses indicates that the fuse used is fast operating type. For continued protection against fire hazard, replace with same type fuse. For fuse rating refer to the marking adjacent to the symbol. Ce symbole indique que le fusible utlise est a rapide. Pour une protection permanente, n'untiliser que fusibles de meme type. Ce darnier est la qu le present symbol est appse. CIRCUIT NO. PART NO. DESCRIPTION
F901
252258 or 5A-T/UL-ST2 or 252164 5A-UL/T-237
2. To initialize the unit
This device employs a microprocessor to perform various functions and operations. If interference generated by an external power supply, radio wave, or other electrical source results in accident which causes the specified operations and functions to operate abnormally. To perform a result, please follow the procedure below. 1.Press and hold down the DVD button, then press the Speakers A button. 2.After "CLEAR" is displayed, the preset memory and each mode stored in the memory, such as surround, are initialized and will return to the factory setting. Unplug the power supply cord from outlet.
3. Safety-check out
After correcting the original service problem, perform the following safety check before releasing the set to the customer. Connect the insulating-resistance tester between the plug of power supply cord and screw on the back panel. Specifications: 3.3Mohm+/-10% at 500V.
4. Memory Preservation
This unit does not require memory preserv ation batteries. A built-in memory power back-up system preserv es the contents of the memory during po wer f ailures and even when the unit is unplugged. The unit must be plugged in order to char ge the back-up system. The memory preserv ation period after the unit has been unplugged v aries depending on climate and placement of the unit. On the average, memory contents are protected over a period of a fe w weeks after the last time the unit has been unplugged. This period is shorter when the unit is exposed to a highly humid climate.
|
|
|
> |
|