|
Usuarios conectados
Actualmente hay 5744 visitantes online.
|
Productos
|
Información
|
Destacado
|
|
|
|
|
No hay comentarios de productos.
1-2-3. Self-diagnosis Code Table
Self-diagnosis Code
Repaired by:
Block Function
Detailed Code
Symptom/State
Correction
C
1
3
0
1
C E
3 6
2 1
0 0
1 0
The internal memory has experienced a format error. �Memory Stick Duo� is unformatted. �Memory Stick Duo� is broken. �Memory Stick Duo� type error The camera cannot read or write data on the �Memory Stick Duo�. Trouble with hardware
Format the internal memory.
E
6
1
1
0
E E
6 6
2 2
0 1
2 0
E
6
2
1
1
E
6
2
1
2
E E E
6 9 9
2 1 2
2 0 0
0 1 0
Format the �Memory Stick Duo�. Insert a new �Memory Stick Duo�. Insert a supported �Memory Stick Duo�. Turn the power off and on again, or taking out and inserting the �Memory Stick Duo� several times. Turn the power off and on again. Retry turn the power on by the power switch. If it does not Difficult to adjust focus recover, check the focus reset sensor of lens block (pin 6 of (Cannot initialize focus) CN402 on the SY-171 board). If it is OK, check the focus motor drive IC (IC401 on the SY-171 board). Retry turn the power on by the power switch. Check the zoom reset sensor of lens block (pin 9 of CN402 on the SY-171 Zoom operations fault board) when zooming is performed when the zoom button is (Cannot initialize zoom lens.) operated. If it is OK, check the zoom motor drive IC (IC401 on the SY-171 board). Check or replacement of the IC for steadyshot (IC503 on the SYAbnormality of IC for steadyshot. 171 board). Check or replacement of the IC for steadyshot (IC503 on the SYLens initializing failure. 171 board). Check the HALL element (PITCH) of optical image stabilizer (pin ea, es of CN402 on the SY-171 board). If it is OK, check Lens overheating (PITCH). PITCH angular velocity sensor (SE502 on the SY-171 board) peripheral circuits. Check the HALL element (YAW) of optical image stabilizer (pin ed, ef of CN402 on the SY-171 board). If it is OK, check YAW Lens overheating (YAW). angular velocity sensor (SE501 on the SY-171 board) peripheral circuits. Check the OIS temp sensor of optical image stabilizer (pin wa of Abnormality of thermistor. CN402 on the SY-171 board). Abnormality when flash is being charged. Checking of flash unit or replacement of flash unit. (Note) Non-standard battery is used. Use the compatible battery only.
Note: After repair, be sure to perform �1-3. PROCESS AFTER FIXING FLASH ERROR�.
1-3. PROCESS AFTER FIXING FLASH ERROR
When �FLASH error� (Self-diagnosis Code E : 91 : 01) occurs, to prevent any abnormal situation caused by high voltage, setting of the flash is changed automatically to disabling charge and flash setting. After fixing, this setting needs to be deactivated. Flash error code can be initialized by the operations on the HOME screen.
Method for Initializing the Flash Error Code
Initialize
Initializes the setting to the default setting. The images stored in the internal memory are retained.
1 Select [Initialize] with v/V/b/B, then press z. The message �Initialize all settings� appears. 2 Select [OK] with v, then press z. The settings are reset to the default setting.
To cancel the resetting
Select [Cancel] in step 2, then press z.
� Make sure that the power is not disconnected during resetting.
DSC-T100_L2 1-2
|
|
|
> |
|