13. Putting into operation
Technical data:
Model Type Gross volume Mains operation Input Energy consumption Climate class Refrigerant DR 130 MF 20-60 31 litre 220 - 240V (AC) 90W 0.99 kWh/24h N 245g NH3 +H2O DR 140 MF 20-60 41 litre 220 - 240V (AC) 90W 1.07 kWh/24h N 245g NH3 +H2O
13.1 Connecting to electrical mains
The appliance may only be operated from nominal voltage mains as shown on the data plate. The appliance mains plug may be connected to a mains socket earthed in accordance with regulations. Any electrical work required to install this appliance should be carried out by a qualified electrician or competent person. The manufacturer declines any liability should these safety measures not be observed. Electrical Requirements Before switching on, make sure the electricity supply voltage is the same as that indicated on the appliance rating plate.
Only for UK: The appliance is supplied with a 3 amp plug fitted. In the event of having to change the fuse in the plug supplied, a 3 amp ASTA approved (BS 1362) fuse must be used. Should the plug need to be replaced for any reason, the wires in the mains lead are coloured in accordance with the following code: Green and Yellow: Blue: Brown: Earth Neutral Live
The wire coloured green and yellow must be connected to the terminal marked with the letter �E� or by the earth symbol or coloured green and yellow. The wire coloured blue must be connected to the terminal �N� or coloured black. The wire coloured brown must be connected to the terminal marked �L� or coloured red. Upon completion there must be no cut, or stray strands of wire present and the cord clamp must be secure over the outer sheath.