b. By Adjusting the Position of the Side Guide Plate of the ADF Pickup Tray 1) Remove the three screws [1], and detach the cover [2].
[2] [1]
F05-101-13 2) Loosen the mounting screw [3], and remove the screw [4] from the side of the positioning hole; then, fit it loosely in the adjusting long hole [5]. 3) Move the original width volume unit [6] to the front or the rear to make adjustments. 4) Tighten the lightly loosened screw [3] and the screw [4] fitted in the adjusting long hole [5]. 5) Mount the cover [2]. 6 ) Make a print of the test chart once again, and check that the image meets the standards.
[6] [5]
[3]
[4]
If A
1 mm, move the volume unit
[6] to the front. If B 1 mm, move the volume unit [6] to the rear. F05-101-14