Configuring the System
Setting the synchronization mode
The CSP-5000E System Controller supports both line lock and VD-S. If a Sony VD-S lock camera is installed, you can turn on the VD setting to enable external syncronization.
4 5
Use the cursor keys to cycle through the options: OFF, and ON. Select �ON� for a Sony VD-S lock camera. Repeat the same procedure with other cameras. When you are ready, press the SET key to accept the changes.
Limiting the pan/tilt unit movement
Depending on the receiver used, you can use the �P/T LIMIT� setting to limit the pan/tilt unit movement in horizontal and vertical directions. This is available only when the receiver type of the camera is �TWIST PAIR.�
3
Select a receiver number. If necessary, press the NEXT or PREVIOUS key to see other pages. Then press the SET key.
P/T LIMIT � LEFT RIGHT UP DOWN CLEAR
1
From the main menu, select �INPUT CONFIGURE� and then press the SET key.
INPUT CONFIGURE � SOURCE ID CABLE COMPENSATION RECEIVER TYPE VD P/T LIMIT
1
From the main menu, select �INPUT COFIGURE� and then press the SET key.
INPUT CONFIGURE � SOURCE ID CABLE COMPENSATION RECEIVER TYPE VD P/T LIMIT
4
Use the cursor keys to select the direction you want to limit (RIGHT LIMIT in this example) and then press the SET key.
2
Select �VD� and then press the SET key.
VD � CAM 1 2 3 4 5 6 7 8 TYPE OFF OFF OFF OFF OFF OFF OFF OFF
2
Select �P/T LIMIT� and then press the SET key.
P/T LIMIT SELECT RECEIVER NO. �1 9 17 2 10 18 3 11 19 4 12 20 5 13 21 6 14 22 7 15 23 8 16 24 25 26 27 28 29 30 31 32
RIGHT LIMIT SETTING
5 6 7
Use the joyball to control the pan/tilt unit so that the camera moves to the rightmost position where you want to limit the movement. Press the SET key. Repeat the above procedure to limit the movement in other directions.
3
Select a camera number. If necessary, press the NEXT or PREVIOUS key to see other pages.
Note that only the receiver numbers whose �RECEIVER TYPE� is set to �TWIST PAIR� in the RECEIVER TYPE menu.
To clear the limit in all directions Select �CLEAR� in step 4 and then press the SET key.
32(EN)