: For left side piping, piping connection for liquid should be about 14 mm from this line. For left side piping, piping connection for : gas should be about 56 mm from this line. For left side piping, piping connecting cable should be about 785 mm from this line. :
1. Mount the installation plate on the wall with 5 screws or more. / (If mounting the unit on the concrete wall consider using anchor bolts.) - Always mount the installation plate horizontally by aligning the marking-off line with the thread and using a level gauge. 2. Drill the piping plate hole with ø70 mm hole-core drill. - Line according to the arrows marked on the lower left and right side of the installation plate. The meeting point of the extended line is the centre of the hole. Another method is by putting measuring tape at position as shown in the diagram above. The hole centre is obtained by measuring the distance namely 150 mm and 125 mm for left and right hole respectively. - Drill the piping hole at either the right or the left and the hole should be slightly slanted to the outdoor side.
11.2.3. TO DRILL A HOLE IN THE WALL AND INSTALL A SLEEVE OF PIPING
1. Insert the piping sleeve to the hole. 2. Fix the bushing to the sleeve. 3. Cut the sleeve until it extrudes about 15 mm from the wall.
Caution When the wall is hollow, please be sure to use the sleeve for tube ass�y to prevent dangers caused by mice biting the connecting cable.
4. Finish by sealing the sleeve with putty or caulking compound at the final stage.