Hitachi CML171SXW LCD Monitor Service Manual (v1.1)
5. General Connection and Applications
Procedures for installing and using this CML171SX LCD monitor are described as below.
5.1 Connecting the monitor to the computer
1) Place the display on a flat, sturdy surface. Choose an area free from excessive heat, moisture, and sunlight. Avoid possible sources of electromagnetic interference, such as transformers, motors, and fluorescent lighting. 2) Locate the AC power adapter with attached power cable and then connect the power cable to the power jack on the back of the display. Plug the three-prong power cord into a power outlet, and plug the other end into the AC power adapter. The three-prong power cord is a shielded type and is provided as a safety precautions to ensure proper electrical grounding.
Plug the D-SUB 15-pin analog signal cable into the Analog Input port on the back of the display. Connect the other end of the signal cable into your computer�s VGA output port. The assignment of the pins of the connector is as follows:
Pin Assignment of 15-pin D-SUB connector 1 2 3 4 5 6 7 8
Red Video Green Video Blue Video Monitor Ground DDC-Return Red Ground Green Ground Blue Ground
9 10 11 12 13 14 15
+5V for DDC circuit Logic Ground Monitor Ground DDC-Serial Data H-Sync. V-Sync. DDC-Serial Clock
9
|