OTHER ADJUSTMENTS
Adjustment of the Position of the Scanner and 2nd/3rd Mirrors Carriage
Requirement � With the Scanner Assy fixed to the Scanner Drive Cables, there should be no gap between the Scanner/Mirrors Carriage Positioning Jig and the Scanner and also between the Scanner/Mirrors Carriage Positioning Jig and the 2nd/3rd Mirror Carriage. This adjustment must be made in any of the following cases: � The Scanner Drive Cable has been replaced. � The Scanner Fixing Bracket has been removed from the Scanner Drive Cable. � The Scanner Drive Cable comes unwound. Adjustment Procedure 1. Remove the IR Rear Upper Cover, IR Front Cover, IR Right Cover, and Original Glass. 2. Move the Scanner Assy so that the Scanner Positioning Screw is aligned with the hole in the upper frame. 3. Insert a screwdriver into the hole in the upper frame and loosen the Scanner Positioning Screw.
4004D218AA
NOTE � Do not remove the Scanner Positioning Screw.
Scanner positioning Screws
4004D203AA
4. Install the Scanner Positioning Jigs between the Scanner Assy and the 2nd/3rd Mirrors Carriage Assy.