To select the mode and service item and change data value
+ Highlight the desired adjustment mode by using the Pv or Pw button and then press the F/OK button. + To select the adjustment item, use the Pv or Pw button. + To change the service data, use the Volume -(LEFT) or Volume + (RIGHT) button. + The data which is set in the service mode is stored into the memory IC automatically. REGULAR mode WIDE mode
REGULAR 1, AGC
38
WIDE 1. P V-P
1F
Adjustment No. and Item name
Adjustment Data
Adjustment No. and Item name
Adjustment Data
Exit from the Service Mode
+ Press the RECALL button or turn off the TV set by using the Mains switch.
INITIALISATION OF MEMORY IC
To initialise the memory IC (IC803), press and hold the NORMAL button on the remote control and then press the Pv button on the front panel of the TV set, and then turn the Mains switch Off and On. Now the initialisation is completed. When the memory IC is initialised, all of the service data (option data and service adjustment data) stored in the IC are reset to the default value. It is necessary to readjust the service adjustments listed on pages 7 & 8.