For the Installer
� When used as an extractor unit, the hood must be fitted with a 150mm diameter hose. � Should there already be a pipe of diameter 125 mm that ducts to the outside through the walls or roof, it is possible to use the 150/ 125 mm reduction flange provided. In this case the hood will be slightly more noisy. � When installing the hood, make sure you respect the following minimum distance from the top edge of the cooking hob/ring surfaces: electric cookers 500 mm gas cookers 650 mm coal and oil cookers 700 mm min. � The national standard on fuel-burning systems specifies a maximum depression of 0.04 bar in such rooms. � The air outlet must not be connected to chimney flues or combustion gas ducts. The air outlet must under no circumstances be connected to ventilation ducts for rooms in which fuel-burning appliances are installed. 4