- Discharging operations
1. When the OPEN key or the ACC is turned �ON�(or detach grille installing ), (2 sec. after) the position motor will be activated under the high speed mode.
2. When the longitudinal position sensing switch (PUSH SW)/(LIFT SW) turns H - L, the position motor will be stopped and, at the same time, the angle motor will be activated at high speed.
3. When the electric potential of the angle encoder reaches 90° (Reference 0° potential + 3.047V), the angle motor will be stopped. (Braking mode) However, if the preceding angle is being memorized, the angle motor will keep running until the memorized angle can be obtained.
90° potential or the memorized position
- Storage operation
1. When the CLOSE key is operated (or 6 sec. after turning �OFF� the ACC while the automatic openclose setting is being turned �ON�), the angle motor will be activated at low speed.
2. At 750ms after the angle 0° potential has been reached, the angle motor will be stopped and the position motor will be activated at high speed. The system will go into stopping movement at the point where the PULL SW is turned �ON� by detection or when the error time is over.