|
Usuarios conectados
Actualmente hay 6020 visitantes online.
|
Productos
|
Información
|
Destacado
|
|
|
|
|
No hay comentarios de productos.
AVIC-505
6.2 CHECKING THE GRATING
- Checking the Grating After Changing the Service Pickup Unit
· Note : Unlike previous CD mechanism modules the grating angle of the Pickup unit cannot be adjusted after the Pickup unit is changed. The Pickup unit in the CD mechanism module is adjusted on the production line to match the CD mechanism module and is thus the best adjusted Pickup unit for the CD mechanism module. Changing the Pickup unit is thus best considered as a last resort. However, if the Pickup unit must be changed, the grating should be checked using the procedure below. · Purpose : To check that the grating is within an acceptable range. · Symptoms of Mal-adjustment : If the grating is off by a large amount symptoms such as being unable to close tracking, being unable to perform track search operations, or track searching taking a long time, may appear. · Method : · Measuring Equipment · Measuring Points · Disc · Mode
· Oscilloscope, Two L.P.F. · E, F, REFOUT · ABEX TCD-784 · TEST MODE
L.P.F. E REFOUT 100k� 390pF Xch Ych
Oscilloscope Oscilloscope
F REFOUT
100k� 390pF L.P.F.
CONTROL UNIT
· Checking Procedure 1. In test mode, load the disc and switch the 5V regulator on. 2. Using the � and � buttons, move the Pickup unit to the innermost track. 3. Press key � to close focus, the display should read "91". Press key MENU to implement the tracking balance adjustment the display should now read "8X". Press key � 4 times. The display will change, returning to "8X" on the fourth press. 4. As shown in the diagram above, monitor the LPF outputs using the oscilloscope and check that the phase difference is within 75° . Refer to the photographs supplied to determine the phase angle. 5. If the phase difference is determined to be greater than 75° try changing the Pickup unit to see if there is any improvement. If, after trying this a number of times, the grating angle does not become less than 75° then the mechanism should be judged to be at fault. · Note Because of eccentricity in the disc and a slight misalignment of the clamping center the grating waveform may be seen to "wobble" ( the phase difference changes as the disc rotates). The angle specified above indicates the average angle. · Hint Reloading the disc changes the clamp position and may decrease the "wobble".
64
|
|
|
> |
|