|
Usuarios conectados
Actualmente hay 5990 visitantes online.
|
Productos
|
Información
|
Destacado
|
|
|
|
|
No hay comentarios de productos.
ADJUSTMENT <TUNER/FRONT>
< TUNER SECTION > < EZ ONLY >
1. Clock Frequency Check Settings : � Test point : TP2 (CLK) Method : Set to MW 1602kHz and check that the test point is 2052kHz ± 45Hz. 2. MW VT Check Settings : � Test point : TP1 (VT) Method : Set to MW 1602kHz and check that the test point is less than 8.0V. Then set to MW 531kHz and check that the test point is more than 0.6V. 3. MW Tracking Adjustment Settings : � Test point : TP5 (Lch), TP6 (Rch) � Adjustment location : L981 (1/3) Method : Set to MW 999kHz and adjust L981 (1/3) so that the test point becomes maximum. 4. LW VT Adjustment Settings : � Test point : TP1 (VT) � Adjustment location : L942 Method : Set to LW 144kHz and adjust L942 so that the test point becomes 1.3V ± 0.05V. Then set to LW 290kHz and check that the test point is less than 8.0V. 5. LW Tracking Adjustment Settings : � Test point : TP5 (Lch), TP6 (Rch) � Adjustment location : L941 ........................... 144kHz TC942 ......................... 290kHz Method : Set up TC942 to center before adjustment. The level at 144kHz is adjusted to MAX by L941. Then the level at 290kHz is adjusted to MAX by TC942. 6. AM IF Adjustment Settings : � Test point : TP5 (Lch), TP6 (Rch) � Adjustment location : L772 ........................... 450kHz 7. FM VT Check Settings : � Test point : TP1 (VT) Method : Set to FM 108.0MHz and check that the test point is less than 8.0V. Then set to FM 87.5MHz and check that the test point is more than 0.5V. 8. FM Tracking Check Settings : � Test point : TP5 (Lch), TP6 (Rch) Method : Set to FM 98.0MHz and check that the test point is less than 13dBµV. 9. DC Balance / Mono Distortion Adjustment Settings : � Test point : TP3, TP4 (DC balance) : TP5(Lch), TP6(Rch) (Distortion) � Adjustment location : L771 � Input level : 60dBµV Method : Set to FM 98.0MHz and adjust L771 so that the voltage between TP3 and TP4 is 0V ± 300mV. Next, check the distortion is less than 1.3 %.
< TUNER SECTION > < U ONLY >
1. Clock Check Settings : � Test point : TP2(CLK) Method : Set to AM 1710kHz and check that the test point is 2160kHz ± 45Hz. 2. AM VT Check Settings : � Test point : TP1(VT), Method : Set to AM 1710kHz, AM 530kHz and check that the test point is less than 8.5V(1710kHz) and more than 0.6V(530kHz). 3. AM Tracking Adjustment Settings : � Test point : TP8(Lch), TP9(Rch) � Adjustment location : L981(1/3) ...................................... 1000kHz Method : Set to MW 1000kHz and adjust L981(1/3) so that the test point is max. 4. FM VT Check Settings : � Test point : TP1(VT) Method : Set to FM 108.0MHz and check that the test point is less than 8.0V. Then set to FM 87.5MHz and check that the test point is more than 0.5V. 5. FM Tracking Check Settings : � Test point : TP9(Lch), TP9(Rch) Method : � Set to FM 98.0MHz and check that the test point is less than 9.0dB. 6. AM IF Adjustment Settings : � Test point : TP8(Lch), TP9(Rch) � Adjustment location : L772 ................................................ 450kHz 7. DC Balance / Mono Distortion Adjustment Settings : � Test point : TP3, TP4 (DC Balance) TP8(Lch), TP9(Rch) (Distortion) � Adjustment location : L771 � Input level : 60dBµV Method : Set to FM 98.0MHz and adjust L771 so that the voltage between TP3 and TP4 becomes 0V ± 0.04V. Next, check that the distortion is less than 1.3%.
< FRONT SECTION >
1. µ-CON OSC Adjustment Settings : � Test point : TP1 and GND � Adjustment location : L801 Method : Insert AC plug while pressing POWER and ECO key. Adjust L801 so that the frequency at the test point is 78.40Hz ± 0.08Hz.
� 56 �
|
|
|
> |
|