AV-14F3/AV-1435 AV-1435EE/AV-1435TEE AV-14FMT3/AV-1438 AV-14FMG3/AV- 14FMG 3B
Measuring instrument Signal gener ator Remote control unit
Item Ad justment of VER. LIN. & VER. SCURVE
Test point
Ad justment part 4. VER. L IN. 5. VER. SCURVE � When the vertical
Description linearity has been deteriorated
rem arkably, perform the following steps. 15. Input a cross -hatch signal. 16. Select 4. VER. LIN. with the MENU �/� key. 17. Set the initial s etting value of 4. VER LIN. with the MENU - / + key. 18. Select 5. VER. SCURVE with the MENU �/ � key. 19. Set the initial setting value of 5. VER. SCURVE with the MENU - / + key.
T OP
CEN TER
20. Adjust 4. VER. LIN. and 5. VER. SCURVE so that the spaces of each line as shown in Fig.3 on TOP, CENTER and BOTTOM become uniform.
BOTT OM
Fig.3
Make sure that the adjustment is properly done on the screen of 60Hz mode. [NOTE] " Adjust to make both 50Hz & 60Hz are the same v. size and fine straight line. " When adjust again, adjust 50Hz mode first.
" When adjust in 60Hz mode, only 60Hz mode is adjust.
VSM PRESET SETTING
Item Measuring instrument Remote control unit Test point Ad justment part Description
Setting of VSM PRESET
TINT COLOUR BRIGHT CONT . SHARP
1. Enter the SERVICE MENU. 2. Select 4. VSM PRESET from the SERVICE MENU. 3. Select BRIGHT with the PICTURE MODE key. 4. Adjust the MENU �/� and MENU - / + key to bring the s et values of TINT � SHARP to the values shown in the below table. 5. Respectively select the VSM PRESET mode for SOFT and STANDARD, and make s imilar adjustment as in 3 above.