Open the "Port setup" tab, and enter "115200" in the column of bit/sec. If the above communication speed cannot be set, select and set one of the following speeds. 9600/19200/38600/57600
10) Select the communication speed on the option menu. (Set the communication speed same as what is set in procedures 6) and 7).)
11) Select the data file to be copied (written) to the Flash ROM installed to the Write socket on the ICU MAIN PWB in procedure 1). (11-1) Double-click the "Simulation Command List " holder. 7) Set the communication speed on the machine side. The set value of communication speed on the computer side must be the same as that on the machine side. (7-1) Enter the simulation 49-2 mode.
(11-2) Double-click the "Special" holder. (11-3) Double-click the "Program Download" file. (11-4) The message of "Program Download OK ?" is displayed. Press the OK button. (7-2) Press the key of the same communication speed as what is set in procedure 8). (The set communication speed is highlighted.) Cancel the simulation 49-2. (11-5) Select the data (PWB name) to be written and click the START button.
(7-3)
8) Enter the simulation mode 49-1 mode, and press the ENTER key. (The machine enters the download (Flash ROM writing) mode.)
(11-6) Select the data file to be written, and click the "Open" button. 9) Start the download program on the computer side. (Double-click the Mainte.exe file.)
With the above procedure, downloading (writing to the Flash ROM) is started. (NOTE) Selection of data files to be written determines whether a source ROM (which includes the latest version program and the Flash ROM copy program) or a ROM which has only the latest version program is made. AR-C260/C260M ROM VERSION UP 12 - 8